Greetings from AMX Global Customer Service,


New Download Updates are now available and can be obtained by following the link/directions in each of the updates below. Here’s a quick overview of what's in this update:


Applications

  • NetLinx Studio
  • AutoPatch BoardConfig
  • UDM-RX02 Firmware
  • UDM-0102 Firmware
  • Modero MVP-5100 Touch Panel Firmware
  • Modero MVP-5150 Touch Panel Firmware
  • Modero MVP-5200i Touch Panel Firmware


Device Modules

 

  • Yamaha BD-S1900 DVD Module
  • Epson PowerLite 1735W Video Projector Module


Update 1:
NetLinx Studio v.3.1.374
http://www.amx.com/techcenter/downloadConfirm.asp?fn=/assets/applicationFiles/NetLinxStudioSetup.exe


Release Date: November 23, 2009

Initial Release:

  • Corrected the problems with the reported crashes when starting up large NetLinx Studio workspace files and during the "Save and Compile" processes
  • Updating the Device Mapping list (in the Workspace and for Auto-Suggest/Auto-Complete) when saving a source code file
  • Ability to transfer an individual JAR file from the "Other" tab located in the "Add Files" dialog for transfer
  • The IR Data tab is updated properly when adding/removing IRL/IRV files from the Workspace tab
  • Corrected a number of problems within the TELNET windows
  • The "Find" dialog is working in the File Compare utility window
  • Various problems with the "Device Mapping" dialog have been corrected
  • Problems with updating the communication information in the "Master Communications Settings" dialog have been corrected
  • The problem with the correct communication settings selected when starting the "Reboot the Master Controller" dialog has been corrected


Update 2:
AutoPatch BoardConfig v.1.4.1
http://www.amx.com/techcenter/downloadConfirm.asp?fn=/assets/applicationFiles/BoardConfig_1_4_1.exe


Release Date: December 01, 2009


New Feature:

  • Added DGX HD-15 TX Wizard


Update 3:
UDM-RX02 Firmware v.1.44
http://www.amx.com/techcenter/downloadConfirm.asp?fn=/assets/firmwareFiles/SW-UDMRX02-01A_v1_44.zip


Release Date: December 01, 2009

New Features:

To leverage the new features, you must have the following firmware versions: UDM-0102 v1.44 or above, UDM-1604C v1.45.10 or above.

Changes in This Release:

  • Added support for higher serial settings (up to 115200, N,O,E)
  • Added support for new AMX remote (RC05)
  • Fixed problem with memory failure when used with frequent UDP commands
  • Added version number reporting
  • Fixed UART hardware overrun and lockup issues
  • Rewritten link (from UDM) packet driver for better serial port performance


Update 4:
UDM-0102 Firmware v.1.00.48
http://www.amx.com/techcenter/downloadConfirm.asp?fn=/assets/firmwareFiles/SW-UDM0102-01A_v1_00_48.zip


Release Date: December 04, 2009

Prerequisites:

Ensure AMX Remote RC05 User Control is set to default if user wishes to switch inputs from other remotes (Sky etc). To leverage the new features, you must have the following firmware versions: UDM-RX02 v1.44 or above.

Changes in This Release:

  • Web pages change to same look and feel as the 1604C
  • Sync now defaults to common mode
  • Added support for key presses to be available via UDP
  • Added UDP command to connect video only
  • Added custom code value support in the user control page
  • Added support for control codes to be issued as separate digits - a custom control code of "2 3 4" will output 2, then 3, then 4
  • Added support for new AMX remote (RC05)
  • Added support for DirectTV remote
  • Non AMX remotes now default to passthrough mode, and have no User Control page associated with them
  • Control pull downs have been expanded to include all RC05 remote functions
  • Improved serial - including 1200 to 115200, O,E and N via separate pull downs for speed and parity Serial return path algorithm
  • Completely revised for more reliable serial data from RX to 102
  • Protocols page now shows % used for loaded protocols and corrections to memory allocation to avoid overflows
  • Rx Version number can be read in the Port page (click on Rx version, update then Rx version)
  • Web server modified to operate correctly with IE7 and Windows Vista
  • Fixed a problem where setting skew values would reset sync options
  • Loopback of Power Toggle, Vol up/down and mute is automatic with RC05 remote


Update 5:
Modero MVP-5100 Touch Panel Firmware v.2.66.18
http://www.amx.com/techcenter/downloadConfirm.asp?fn=/assets/firmwareFiles/SW5966-08_MVP5100_v2_66_18.kit


Release Date: December 03, 2009

Prerequisites:

v2.60.32 v2.61.9, or v2.65.21 must be installed and running prior to downloading v2.66.18

Changes in This Release:

  • Added Battery Type field to Battery Settings in order to identify the installed battery pack.

Known Issues:

  • Disable Timeout on external Power gets disabled after each reboot.
  • Only MVP8400 style power management is implemented.
  • Touch screen must be held until AMX logo displays to wake on touch.
  • Keyboard/keypad button visual feedback may be not display for 'quick touches'.


Update 6:
Modero MVP-5150 Touch Panel Firmware v.2.66.18
http://www.amx.com/techcenter/downloadConfirm.asp?fn=/assets/firmwareFiles/SW5966-07_MVP5150_v2_66_18.kit


Release Date: December 03, 2009

Prerequisites:

v2.60.32 , v2.61.9, or v2.65.21 must be installed and running prior to downloading v2.66.18

Changes in This Release:

  • Added Battery Type field to Battery Settings in order to identify the installed battery pack.

Known Issues:

  • Disable Timeout on external Power gets disabled after each reboot.
  • Only MVP8400 style power management is implemented.
  • Re-authentications in EAP mode can take longer than normal depending on AP timeout settings (1-1000) seconds. This can happen during roaming.
  • Fails to connect to WAP on reboot using multiple SSIDs and multiple hidden beacons.
  • Loss of connection after sending TPD4 page in NDP(UDP)/URL(UDP) mode.
  • Touch screen must be held until AMX logo displays to wake on touch.
  • Keyboard/keypad button visual feedback may be not display for 'quick touches'.


Update 7:
Modero MVP-5200i Touch Panel Firmware v.2.66.18
http://www.amx.com/techcenter/downloadConfirm.asp?fn=/assets/firmwareFiles/SW5966-01_MVP5200i_v2_66_18.kit


Release Date: December 02, 2009

Prerequisites:

  • If the panel firmware is older than v2.60.64 the firmware upgrade process consists of the following steps:
    1. Upgrade to v2.60.64 before proceeding to step 2.
    2. Upgrade panel using prep kit file "SW5966-01_MVP5200i_v2_66_18-prep.kit". The panel must be left idle for least 15 minutes AFTER the transfer. The panel will reboot several times and will overwrite any user pages that are present. It is very important that the upgrade process not be interrupted once the file transfer is complete, so external power is required. The panel should now have v2.66.18 loaded. Upgrade is complete.
  • If upgrading from 2.65.21 or earlier you must use the prep kit file "SW5966-01_MVP5200i_v2_66_18-prep.kit". This kit contains an intermediate kit file as well as the actual v2.66.18 kit file, so this is the only kit file you need to transfer. The panel must be left idle for least 15 minutes AFTER the transfer. The panel will reboot several times and will overwrite any user pages that are present. It is very important that the upgrade process not be interrupted once the file transfer is complete, so external power is required.
  • If upgrading from v2.66.17 or later you may use the "SW5966-01_MVP5200i_v2_66_18.kit" file directly without requiring the intermediate prep kit file.
  • Requires latest TPD4 Software (2.11.611 or later) to use new Fast Dynamo feature.
  • Requires latest MET-ECOM firmware (1.01.15 or later) to use the Fast Dynamo feature with MET-ECOM video.
  • Requires new SIP NetLinx module and panel pages in order to support automatic accelerated video and SIP in conjunction with a MET-ECOM device. As a workaround to achieve accelerated video, the existing module can be modified by searching for "%Fstream_cam_wg.mjpeg" and replacing with "%Fstream_cam_eth.mjpeg". Additionally, the "Dynamo Resource" box must be checked for the camera resource in the TPD4 Resource Manager.

Changes in This Release:

  • Added Battery Type field to Battery Settings in setup pages. This field indicates which type of battery is currently installed in the unit.

Known Issues:

  • Loss of connection may occur after sending TPD4 page in NDP(UDP)/URL(UDP) mode.
  • Panel is unable to display two fast dynamo images simultaneously. If two are ever required an additional resource should be created in the TPD4 Resource Manager without "Dynamo Resource" specified.
  • When an image is designated "Dynamo Resource" in the TPD4 Resource Manager, only one image should be visible at any one time because only one can be accelerated at a time. If multiple images are required (e.g. a popup viewing the same image as an underlying page), then a separate Resource should be created in the Resource Manager without the "Dynamo Resource" box checked, and that resource should be used anywhere a duplicate image is needed.
  • Fill color on a button with Fast Dynamo is always black.
  • Alpha blending is not supported for Fast Dynamo buttons. If any text or other buttons appear on top of a button with Fast Dynamo video, the Overall Opacity is ignored and the graphics are overlaid on top of the video rather than blended. If blending is required, standard dynamo video can still be used but the video will not be accelerated.
  • On rare occasion, wireless security settings can't be changed. If a reboot does not correct this, it may be necessary to reset to factory defaults via the protected setup page, then modify the wireless settings as desired.
  • Deep sleep has been disabled altogether due to 802.11 issues.
  • It is possible to design pages that will allow the Master Volume to be controlled. This can cause distortion in audio should the volume be set to a high value (higher than 25).
  • In some low memory situations, certain wireless functions (e.g. site survey) may cease to work.
  • Occasionally after entering the correct password to undock a panel, it may display a second keyboard asking for a password after the panel is removed. The new keyboard may be aborted with no adverse affects.


Update 8:
Yamaha BD-S1900 DVD Module - v1.0.0 - Initial Release
(Click to visit the InConcert Resource Center to search for the device by manufacturer and model name.)

Release Date: December 01, 2009




Update 9:
Epson PowerLite 1735W Video Projector Module

Includes models:

PowerLite 260 EB-1720 EMP-1700
PowerLite 1700c EB-1725 EMP-1705
PowerLite 1705c EB-1730W EMP-1710
PowerLite 1710c EB-1735W EMP-1715
PowerLite 1715c EB-S6  
Powerlite 1720 EB-W6  
PowerLite 1725 EB-X6  
PowerLite 1730W  
PowerLite 1735  
PowerLite 1735W  
PowerLite EX90  
PowerLite S5  
PowerLite S6  
PowerLite W6  
PowerLite X5  
PowerLite X6  


(Click to visit the InConcert Resource Center to search for the device by manufacturer and model name.)

Release Date: December 02, 2009




 

Sincerely,

Your AMX Global Customer Service Team
3000 Research Drive
Richardson, TX 75082
800.222.0193, option 3 (in the US)
+1.469.624.7400 (outside the US)
service@amx.com

Visit us at amx.com


Suggestions, Questions, Comments? Send an email to: editor@amx.com. This newsletter is produced and copyrighted by AMX. Content may be used for personal use. Publication for commercial use requires written permission from AMX. Terms and Conditions | © 2009 AMX. All rights reserved.

You have received this update because you are subscribed to the AMX Download Update service. We hope that you find this information helpful. To be able to download these updates, you must be an authorized AMX.com Dealer/World Partner. If you do not wish to receive further updates, please unsubscribe by clicking "Safe UnSubscribe" below or to subscribe/unsubscribe to this or any of our newsletter editions, please visit your AMX.com Account Center and click on "Edit Your Account" on the left green navigation bar and then scroll to the bottom of the page. Check any editions you would like to keep or subscribe to and leave any you would not like tokeep or subscribe to unchecked, then click "Submit".