<product>
  <details>
      <discontinued isDiscontinued="yes">
      <replacedByName>NI-4100</replacedByName>
      <replacedByURL>NI-4100.asp</replacedByURL>
    </discontinued>

    <name>NI-4000</name>
    <description>NetLinx® Integrated Controller</description>
    <text>
      <p>The NI-4000 is geared to meet the high-end control and automation requirements
        within the most sophisticated and complex commercial and residential
        installations. This solution is engineered with the same number of ports
        and relays as the NI-3000, plus four NetLinx Control Card slots in order
        to achieve a superior level of built-in control and automation functionality.</p>
      <p>The NI-4000 integrates the largest amount of electronics such as VCR
        and DVD players, projectors, projection screens, lights, HVAC systems,
        security cameras and more. In technology intensive environments, this
        solution can be used to anticipate the future addition of devices and
        control capabilities.</p>
      <p>For businesses experiencing rapid growth and homes looking for greater
        flexibility and customization, the NI-4000 includes the perfect &quot;mix&quot; of
        compatible control formats:
      <ul>
        <li>8 &#8211; IR ports</li>
        <li>8 &#8211; I/O</li>
        <li>8 &#8211; Relays</li>
        <li>7 &#8211; RS-232 / RS-422 / RS-485 Serial ports</li>
        <li>3 &#8211; Communication Networks: ICSNet, AxLink and Ethernet (TCP/IP)</li>
        <li>4 &#8211; NetLinx Control Card Expansion slots that support all NXC
          control cards</li>
      </ul>
	  </p>
      <p><strong>FEATURES</strong>
      <ul>
        <li>Powerful built-in multiport control</li>
        <li>Easy-to-understand control architecture</li>
        <li>Ultra-fast processing. Intelligent and reliable networking</li>
        <li>Robust 32MB of memory, plus expandable 32MB CompactFlash</li>
        <li>900 mA @ 12 VDC</li>
      </ul>
	  </p>
</text>
<tabSections>
<section name="Specifications">
<text>
<p><strong>SPECIFICATIONS</strong></p>	  
      <p><strong>ENCLOSURE:</strong> Metal with black matte finish</p>
      <p><strong>DIMENSIONS (HWD):</strong> 5 3/16&quot; x 17&quot; x 9 5/16&quot; (13.2
        cm x 43.2 cm x 23.7 cm)</p>
      <p><strong>WEIGHT: </strong>9.15 lbs (4.15 kg)</p>
    </text>
	</section>
</tabSections> 
    <graphics>
      <thumbnail>NI-4000</thumbnail>
      <otherResources>
        <resource type="360" linkName="360&#176;">NI-4000</resource>
      </otherResources>
    </graphics>
    <breadcrumbs>
      <crumb>
        <name>Products</name>
        <url>default.asp</url>
      </crumb>
      <crumb><name>Central Controllers</name><url>categoryCentralControllers.asp</url></crumb>
      <crumb>
        <name>NI-4000</name>
        <url>NI-4000.asp</url>
      </crumb>
    </breadcrumbs>
    <FGInfo>
      <FG>
        <name>FG2105</name>
        <description>NetLinx Integrated Controller</description>
      </FG>
    </FGInfo>
  </details>
  <assets>
    <datasheets><datasheet>
<revisionDate>2006-12-18</revisionDate>
<categories>
<category>Central Controllers</category>
</categories>
<name>NI-4000 NetLinx Integrated Controller</name>
<url>/techdocs/datasheets/NI-4000.Datasheet.pdf</url>
<target>_blank</target>
<fileInfo>PDF  |  196 KB</fileInfo>
<products>
<product>NI-4000</product>
</products>
</datasheet></datasheets>
    <aespecs>
      <aespec>
        <revisionDate>2006-4-6</revisionDate>
        <categories>
          <category>NetLinx Controllers</category>
        </categories>
        <priority>60</priority>
        <name>NI-4000 NetLinx Integrated Controller</name>
        <url>/techdocs/EngineeringSpecs/NI-4000-AES.doc</url>
        <target>_blank</target>
        <fileInfo>DOC</fileInfo>
        <products>
          <product>NI-4000</product>
        </products>
      </aespec>
    </aespecs>
    <whitePapers></whitePapers>
    <drawings><drawing>
<categories>
<category>Pictorial (95) Drawings</category>
</categories>
<name>NI-4000 NetLinx Integrated Controller</name>
<file>
<url>/techdocs/952105.pdf</url>
<target>_blank</target>
<fileInfo>PDF</fileInfo>
</file>
<file>
<url>/techdocs/endwgs/952105.dxf</url>
<target>_blank</target>
<fileInfo>DXF</fileInfo>
</file>
<products>
<product>NI-4000</product>
</products>
</drawing></drawings>
    <applicationFiles></applicationFiles>
    <firmwareFiles><firmware display="yes">
<revisionDate>2010-08-26</revisionDate>
<categories>
<category>Central Controllers</category>
</categories>
<name>NI Series (X000) Duet Master Firmware</name>
<version>3.50.439</version>
<url>/assets/firmwareFiles/2105_NI-X000_v3_50_439.zip</url>
<target>_self</target>
<fileInfo>ZIP  |  4.85 MB</fileInfo>
<fileDetails>
<span>
<p><strong>Prerequisites:</strong><br />
  Master build 300 or greater.  (see Programming Information)</p>
<p><strong>Changes in this release</strong>
<ul>
<li>Added support for device TCP/IP address hot-swap to support MVP-9000i</li>
<li>Added support for expedited OFFLINE/ONLINE cycle to support MVP-9000i</li>
<li>Closed VxWorks WDB security hole by removing the WDB agent from the 
  VxWorks kernel. Under the previous firmware versions, the security hole 
  was only exposed when the master had a static IP address. 
  (US-CERT VU#362332)</li>
</ul>
</p>
<p><strong>Known Issues</strong><br />
  None</p>
<strong>Programming Information</strong><br />
  If you currently have a firmware build less than 300, to upgrade to this
  version (or greater) the upgrade requires the following process:

    <ol>
<li>Download kit with build 300 (or greater) - Download of last component 
     will fail</li>
<li>Reboot master</li>
<li>Wait until you have connectivity to the master or you have a blinking
     AxLink status LED. This may take a couple of minutes</li>
<li>Download kit with build 300 (or greater) again - Download should pass</li>
<li>Reboot master</li>
<li>Please wait. This will take a few minutes for file extraction and key SSH
     generation. When you have connectivity to the master or the AxLink LED is
     blinking the master is ready</li>
</ol>
</span>
</fileDetails>
<revisionDate>2010-08-26</revisionDate>
<products>
<product>NI-2000</product>
<product>NI-3000</product>
<product>NI-4000</product>
</products>
</firmware><firmware display="yes">
<revisionDate>2006-04-06</revisionDate>
<categories>
<category>Central Controllers</category>
</categories>
<name>NI Series (X000) Master Firmware</name>
<version>2.32.148</version>
<url>/assets/firmwareFiles/2105_NI-X000_Master_v2_32_148.kit</url>
<target>_self</target>
<fileInfo>KIT | 5.44 MB</fileInfo>
<fileDetails>
<span><strong>New Features:</strong>
<ul>
<li>Added Timeline loop count in Interpreter to handle consecutive zero length timeline events</li>
<li>Added "set timeline loopcnt" command to telnet interface to modify the Interpreter's timeline loop count</li>
<li>Fixed IO channel status reporting</li>
</ul>
</span>
</fileDetails>
<releaseDate>2006-03-13</releaseDate>
<products>
<product>NI-2000</product>
<product>NI-3000</product>
<product>NI-4000</product>
</products>
</firmware><firmware display="yes">
<revisionDate>2009-11-06</revisionDate>
<categories>
<category>Central Controllers</category>
</categories>
<name>NI Series (X000) Device Firmware</name>
<version>1.20.7</version>
<url>/assets/firmwareFiles/SW2105_NI_X000_Device_v1_20_7.kit</url>
<target>_self</target>
<fileInfo>KIT  |  32 KB</fileInfo>
<fileDetails>
<span>
<p><strong>Dependencies:</strong>
<ul>
<li>Requires master firmware 3.50.430 or later.</li>
</ul>
</p>
<p><strong>Changes in this Release:</strong>
<ul>
<li>Fixed issue where serial ports would sometimes drop data.</li>
<li>Fixed missing button release on MIO-IRRX.</li>
<li>Fixed issue where serial ports would not receive data.</li>
<li>Resolved serial port lock ups.</li>
<li>Fixed some 485 tx/rx problems.</li>
<li>Support for XCH command for 4 digit channel.  New XCH modes 5 &amp; 6 added.  These are equivalent to the current modes 1 &amp; 2 except for 4 digit channel numbers.</li>
<li>Increased speed of I/O detection.</li>
<li>Added command to enable/disable check for escape sequences in strings being transmitted.  Commands are ESCSEQOFF and ESCSEQON.  The default behavior is now off (used to be on).</li>
<li>Fixed IR LED #7.</li>
<li>Fixed some issues with XCH command.</li>
<li>Fixed states of IO ports after a reboot.</li>
</ul>
</p>
</span>
</fileDetails>
<releaseDate>2009-11-06</releaseDate>
<products>
<product>NI-2000</product>
<product>NI-3000</product>
<product>NI-4000</product>
</products>
</firmware></firmwareFiles>
    <literature></literature>
    <logosPhotos></logosPhotos>
    <manuals><manual>
<revisionDate>2010-06-30</revisionDate>
<categories>
<category>Central Controllers</category>
</categories>
<name>Programming Guide - NetLinx Integrated Controllers</name>
<url>/techdocs/NetLinxControllers.WebConsole-ProgrammingGuide.pdf</url>
<target>_blank</target>
<releaseDate>2010-06-30</releaseDate>
<version></version>
<fileInfo>PDF  |  4.63 MB</fileInfo>
<products>
<product>NI-700</product>
<product>NI-900</product>
<product>NI-2000</product>
<product>NI-3000</product>
<product>NI-4000</product>
<product>NI-2100</product>
<product>NI-3100</product>
<product>NI-4100</product>
<product>NI-3101-SIG</product>
<product>NXC-ME260/64</product>
<product>DVX-2100HD</product>
</products>
</manual><manual>
<revisionDate>2008-05-29</revisionDate>
<categories>
<category>Central Controllers</category>
</categories>
<name>Hardware Reference Guide - NI-2000/3000/4000 NetLinx Integrated Controllers</name>
<url>/techdocs/NI-X000.HardwareReferenceGuide.pdf</url>
<target>_blank</target>
<releaseDate>2008-05-29</releaseDate>
<version></version>
<fileInfo>PDF  |  1.23 MB</fileInfo>
<products>
<product>NI-2000</product>
<product>NI-3000</product>
<product>NI-4000</product>
</products>
</manual><manual>
<revisionDate>2006-05-10</revisionDate>
<categories>
<category>Central Controllers</category>
</categories>
<name>Instruction Manual - NI-2000/3000/4000 with Firmware Version 139 or Earlier</name>
<url>/techdocs/0602673.pdf</url>
<target>_blank</target>
<releaseDate>2004-10</releaseDate>
<version></version>
<fileInfo>PDF</fileInfo>
<products>
<product>NI-2000</product>
<product>NI-3000</product>
<product>NI-4000</product>
</products>
</manual><manual>
<revisionDate>2006-05-10</revisionDate>
<categories>
<category>Central Controllers</category>
</categories>
<name>Quick Start Guide - NI-4000 with Firmware Version 139 or Earlier</name>
<url>/techdocs/93-2105.pdf</url>
<target>_blank</target>
<releaseDate>2004-10</releaseDate>
<version></version>
<fileInfo>PDF</fileInfo>
<products>
<product>NI-4000</product>
</products>
</manual><manual>
<revisionDate>2006-11-20</revisionDate>
<categories>
<category>Central Controllers</category>
</categories>
<name>Quick Start Guide - NI-4000 NetLinx Integrated Controller</name>
<url>/techdocs/NI-4000.QuickStartGuide.pdf</url>
<target>_blank</target>
<releaseDate>2006-11-20</releaseDate>
<version>REV R</version>
<fileInfo>PDF  |  160 KB</fileInfo>
<otherLanguage>
<language>fr</language>
<url>/techdocs/International Documentation/French/NI-4000.QuickStartGuide.93-2105.French.pdf</url>
<target>_blank</target>
</otherLanguage>
<products>
<product>NI-4000</product>
</products>
</manual><manual>
<revisionDate>2006-05-10</revisionDate>
<categories>
<category>Central Controllers</category>
</categories>
<name>Open SSL Warranty and Licensing Information (For NXC-ME260 and NI-Series Firmware 139 or Earlier)</name>
<url>/techdocs/93-2105-05.pdf</url>
<target>_blank</target>
<releaseDate></releaseDate>
<version></version>
<fileInfo>PDF</fileInfo>
<products>
<product>NXC-ME260</product>
<product>NI-2000</product>
<product>NI-3000</product>
<product>NI-4000</product>
<product>NI-700</product>
</products>
</manual></manuals>
    <tpFiles></tpFiles>
    <visioStencils></visioStencils>
    <presentations></presentations>
    <videos><video>
<revisionDate>2006-03-26</revisionDate>
<categories>
<category>Central Controllers</category>
</categories>
<name>NI Series (X000) NetLinx Integrated Controllers</name>
<url>/assets/videos/NIX000SeriesControllers.mp4</url>
<fileInfo>MP4  |  12.5 MB</fileInfo>
<target>_blank</target>
<products>
<product>NI-2000</product>
<product>NI-3000</product>
<product>NI-4000</product>
</products>
</video></videos>
  <deviceModules></deviceModules></assets>
  <relatedProducts></relatedProducts>
</product>