NXB-CCG

NetLinx® Clear Connect™ Gateway

Description
NXB-CCG, 434 MHz NetLinx Clear Connect Gateway, U.S. and Canada Only
Part #FG2606

GOING GREEN
The AMX Clear Connect Wireless Gateway system can be programmed to turn lights and other AV equipment off when not in use.

TRAINING AVAILABLE
Learn important installation, configuration and programming techniques in the following course(s) from AMX University:

  • Getting Started with AMX Clear Connect

For schedules and registration for these and any AMX University courses, visit www.amx.com/training.

OVERVIEW
The AMX Clear Connect Wireless Gateway connects NetLinx Controllers with Lutron's Clear Connect Dimmers, Switches, Occupancy/Vacancy Sensors and Keypads that are sold by AMX*. The Gateway includes a web interface for simplified integration, configuration, and programming of Clear Connect devices. When integrated with an AMX NetLinx Controller, installers now have a simple and cost-effective path to offer smart room automation that includes light and AV control from a single interface, occupancy sensing, scheduled shutdown and energy management.

COMMON APPLICATIONS
Ideal for new and retrofit applications looking for the least costly way to add light and AV control to a room. Use the Clear Connect Gateway with Lutron's Clear Connect Dimmers, Switches, Keypads, and/or Occupancy/Vacancy Sensors.

FEATURES

  • Clear Connect Enabled – Lutron's patented RF Technology uses a quiet band, essentially free of interference ensuring reliable communication between system devices
  • Perfect Way to Add Light Control – Easily integrates with existing electrical infrastructures – simply replace the light switch
  • Create Light & Control Events with Room Occupancy – Use the Clear Connect Wireless Occupancy Sensor with RMS to automatically power-up and shut-down the lights and AV equipment to maximize energy conservation
  • Simple Web Configuration – Browse to the NetLinx Clear Connect Gateway URL to quickly configure and program Clear Connect Enabled Switches, Dimmers, Keypads and Occupancy/Vacancy Sensors

* Compatible Lutron Dimmers & Switches sold by AMX are listed on AMX.com: http://www.amx.com/products/categoryLightingControls.asp

DEALER BENEFITS

  • Easily Add Light Control – Integrates with existing electrical infrastructures – simply replace the light switch
  • Reliable Light Control – Lutron's patented Clear Connect RF Technology ensures ultra-reliable wireless communication between components
  • Simplified AMX Integration - Use an intuitive web browser to add devices, create scenes, and program the system with no installed software tools

CUSTOMER BENEFITS

  • Ideal For Existing or Retrofit Applications – Wireless light solution can be added to any room
  • Save Energy – Dim a standard halogen or incandescent light bulb by 25% and save 20% energy; dim more, save even more and extend bulb life
  • Automatic Shutdown – Turn off lights and AV equipment that were inadvertently left on
  • Add Convenience and Easily Create the Right Ambiance – At the touch of a button, adjust the lights to give you the right light when you need it, where you want it

SPECIFICATIONS

DIMENSIONS (HWD)

  • Without antenna: 1 1/8" x 2 5/8" x 4 7/16" (2.86 cm x 6.60 cm x 11.23 cm)
  • With antenna: 6 1/2" x 2 5/8" x 4 7/16" (17.15 cm x 6.60 cm x 11.23 cm)

WEIGHT
0.3 lbs (136.08 g)

POWER

  • Input: 100-240VAC 50/60 Hz, 0.3A Max
  • Output DC adapter: 5V DC, 2A
  • Surge Protection: To withstand surge voltages without damage or loss of operation, in accordance with IEEE C62.41-1991 Recommended Practice on Surge Voltages in Low-Voltage AC Power Circuits
  • Power Failure Memory: Should power be interrupted, the Clear Connect Gateway will return to its previous state when power is restored.
  • Power Supply Included for NXB-CCG (FG2606) 434 MHz NetLinx Clear Connect Gateway, U.S. and Canada Only: 5VDC Adapter (WA-10J05FU)
  • Optional Power Supply Required for NXB-CCG-K (FG2606-868) 868 MHz NetLinx Clear Connect Gateway, Europe Only: PS-CCG, 5 VDC, 3 A Power Supply with 2.1 mm Barrel Connector for NXB-CCG-K

ENVIRONMENTAL

  • Operating Temperature: 32° F (0° C) to 104° F (40° C)
  • Operating Humidity: 0% to 90%, non-condensing
  • Indoor use only

ESD PROTECTION
To withstand electrostatic discharge without damage or memory loss, in accordance with IEC 61000-4-2

COMMUNICATIONS

  • Ethernet: Supported IP and IP-Based Protocols: TCP,DHCP, Telnet, HTTP, HTTPS, SSH
  • RF: FG2606 communicates to a maximum 31 Clear Connect devices through 434 MHz RF, FG2606-868 communicates to a maximum of 31 Clear Connect devices through 868 MHz RF
  • USB: Manufacturer use only
  • Protocol: The Clear Connect Gateway supports the ZeroConf auto discovery protocol

FRONT PANEL COMPONENTS

  • Power Status LED: Displays power status and other system status indicators
  • RF LED: Displays the Tx/ Rx activity on the RF link
  • Ethernet LED: Displays the connection status and Tx/ Rx activity on the Ethernet link

REAR PANEL COMPONENTS

  • Cat5 Cable Port: 10/100 port, RJ-45 connector. Maximum cable length: 328 ft (100 m)
  • USB Cable Port: Manufacturer use only
  • Reset Button: Press and hold for 20 seconds to restore the system to the Factory Default settings
  • Power Jack (to DC adapter): (IEC PELV / NECR Class 2)

CERTIFICATIONS
UL, FCC, CUL, IC



Note: Specifications are subject to change. The most current and complete specifications for this product can always be found at AMX.com: AV for an IT World.


TRAINING AVAILABLE
Learn important installation, configuration and programming techniques in the following course(s) from AMX University:

  • Getting Started with AMX Clear Connect

For schedules and registration for these and any AMX University courses, visit www.amx.com/training.

NAME DESCRIPTION PART #
PS-CCG 5 VDC, 3A Power Supply for NXB-CCG-K (Europe Only) (FG423-61)
Feedback | Gear Store | Site Map | Terms & Conditions | Warranty