<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="xsl_productPage.asp?pageName=/products/NXI.asp"?>
<product>
  <details>
    <name>NXI</name>
    <description>NetLinx® Integrated Controller (No Master)</description>
    <text>
<p><strong>OVERVIEW</strong><br />
The NetLinx Integrated Controller provides incredibly powerful
control and networking capabilities and instantly commands
projectors, window treatments, security, lighting and even PCs
with a full array of RS-232/422/485 ports, IR/Serial ports, Inputs/
Output channels and relays. Measuring only 1 rack unit (1RU)
the NXI NetLinx Integrated Controller frees up space for other
components.</p>

<p><strong>COMMON APPLICATION</strong><br />
The NetLinx Integrated Controller's sleek modular design and
compact size make it perfect for open shelves and tables within
home theaters and residences or behind the scenes in a rack used
for commercial applications.</p>
      
<p><strong>FEATURES</strong>
      <ul>
      	<li>6 Configurable RS-232 / RS-422 / RS-485 Serial ports</li>
        <li>12 Relays</li>
        <li>8 IR / Serial ports</li>
        <li>8 Digital I/O ports</li>
      </ul>
	  </p>
</text>
<tabSections>
<section name="Specifications">
<text>
<p><strong>SPECIFICATIONS</strong></p>
<p><strong>DIMENSIONS (HWD)</strong>
      <ul>
        <li>1 3/4” x 17” x 8 13/16” (4.4 cm x 43.2 cm x 22.4 cm)</li>
        <li>RU: 1</li>
      </ul></p>
      
<p><strong>WEIGHT</strong><br />
4.0 lbs (1.8 kg)</p>

<p><strong>POWER</strong><br />
1.09 mA @ 12 VDC</p>

<p><strong>ENCLOSURE</strong><br />
Metal with black matte finish</p>
      
<p><strong>MEMORY</strong>
      <ul>
        <li>64K of IR memory</li>
        	<ul>
            	<li>32K IR memory for IR ports 8-11</li>
                <li>32K IR memory for IR ports 12-15</li>
            </ul>
      </ul>
	  </p>
<p><strong>PORT ASSIGNMENTS</strong>
      <ul>
        <li>Ports 1-6 = RS-232/422/485 Ports</li>
        <li>Port 7 = 12 Relays</li>
        <li>Ports 8-15 = IR/IR Serial Ports</li>
        <li>Port 16 = 8 I/O Channels</li>
      </ul>
	  </p>
      
<p><strong>CERTIFICATIONS</strong><br />
FCC Part 15 Class B, CE, and IEC 60950</p>
      


<p><strong>FRONT PANEL COMPONENTS</strong>
      <ul>
        <li>Master/Hub Card slot: Accepts an NXC-ME260 or Hub Card</li>
		<li>RS-232/422/485 TX/RX LEDs: Six sets of red and yellow LEDs light to indicate
ports 1-6 are transmitting or receiving RS-232, 422, or 485 data:<br />
- TX LEDs (red) blink when transmitting data<br />
- RX LEDs (yellow) blink when receiving data</li>
		<li>Relay LEDs: Twelve red LEDs light to indicate relay channels 1-12 are
active (closed)</li>
		<li>IR/Serial LEDs: Eight red LEDs light to indicate IR/Serial channels 1-8 are
transmitting control data</li>
		<li>I/O LEDs: Eight yellow LEDs light when I/O channels 1-8 are active</li>
		 </ul>
	  	</p>
<p><strong>REAR PANEL CONNECTORS</strong>
      <ul>
        <li>ID Pushbutton: Sets the D:P:S assignment for the NXI</li>
        <li>ICSP LED: Green LED Blinks in unison with the Master card’s NetLinx LED
indicating the ICSP bus is synchronized. This LED flashes rapidly when the NXI
is in ID Mode (see Using the ID Button for details)</li>
        <li>RS-232/422/485 Ports (#1-6): Six RS-232/422/485 control ports with XON/
XOFF (transmit on/transmit off), and CTS/RTS (clear to send/ready to send),
300-230,400 baud:<br />
- Channel range = 1-255<br />
- Channels 1-254 provide feedback only.<br />
- Channel 255 (CTS Push channel) reflects the state of the CTS<br />
- Input if a ‘CTSPSH’ command was sent to the port.</li>
        <li>Relays Port (# 7): Twelve-channel relay port. Channel range = 1-12<br />
- You can connect up to 12 independent external relay devices to the Relay
connectors on the NXI (port 7)<br />
- Connectors labeled A are for common and B are for Output<br />
- Each relay is isolated and normally open</li>
        <li>IR/Serial Ports (# 8-15): Eight IR/Serial control ports that support
high-frequency carriers up to 1.14 MHz:<br />
- Channel range = 1-32,000<br />
- Channels 1-253 (output): IR commands<br />
- Channel 254 (feedback): PowerFail (used with ‘PON’ and ‘POF’ commands)<br />
- Channel 255 (feedback): Power status (when IOLink is set).</li>
        <li>I/O Port (# 16): 8-channel I/O port for contact closure, 0-5 VDC voltage
sensing, or interactive power sensing for IR ports. Channel range = 1-8</li>
      </ul>
      </p>

<p><strong>ENVIRONMENTAL</strong><br />
Heat Dissipation (Typical): 44.7 BTU/hr</p>

<p><strong>INCLUDED ACCESSORIES</strong>
      <ul>
        <li>4 CC-NIRC emitters</li>
        <li>Metal tab strips for commoning adjacent relays</li>
        <li>Rack-mount brackets adapt for rack, wall, or shelf mounting</li>
        <li>NetLinx faceplate</li>
       </ul>
	  </p>
</text>
</section>
<section name="Recommended Accessories">
</section>
</tabSections> 
<icons>
<icon>
			<iconSrc>/assets/coolIcons/aCloserLook.png</iconSrc>
			<params name="aCloserLook">
				<div>
					<img src="../imgs/aCloserLook/NXI_CloserLook.jpg" width='545'/>
				</div>
			</params>
		</icon>
		<icon>
        <params name="countryCode">
          <countryCode>US</countryCode>
        </params>
      </icon>
</icons>
<noteTab>
		<lineBig>6  |  12  |  8  |  8</lineBig>
		<lineSmall>Serial - Relay - IR - Digital I/O</lineSmall>
	</noteTab>
    <graphics>
      <thumbnail>NXI</thumbnail>
    </graphics>
    <breadcrumbs>
      <crumb>
        <name>Products</name>
        <url>default.asp</url>
      </crumb>
      <crumb><name>Central Controllers</name><url>categoryCentralControllers.asp</url></crumb>
      <crumb>
        <name>NXI</name>
        <url>NXI.asp</url>
      </crumb>
    </breadcrumbs>
    <FGInfo>
      <FG>
        <name>FG2101</name>
        <description>NetLinx Integrated Controller (No Master)</description>
      </FG>
    </FGInfo>
  </details>
  <assets>
    <datasheets><datasheet>
<revisionDate>2006-12-18</revisionDate>
<categories>
<category>Central Controllers</category>
</categories>
<name>NetLinx Integrated Controller</name>
<url>/techdocs/datasheets/NXI.Datasheet.pdf</url>
<target>_blank</target>
<fileInfo>PDF  |  84.0 KB</fileInfo>
<otherLanguage>
<language>de</language>
<url>/de/assets/downloadbereich/NXI.datenblatt.pdf</url>
<target>_blank</target>
</otherLanguage>
<products>
<product>NXI</product>
</products>
</datasheet></datasheets>
    <aespecs></aespecs>
    <whitePapers></whitePapers>
    <drawings><drawing>
<categories>
<category>Pictorial (95) Drawings</category>
</categories>
<name>NXI NetLinx Integrated Controller (2 Pages)</name>
<file>
<url>/techdocs/952101.pdf</url>
<target>_blank</target>
<fileInfo>PDF</fileInfo>
</file>
<file>
<url>/techdocs/endwgs/952101.dxf</url>
<target>_blank</target>
<fileInfo>DXF</fileInfo>
</file>
<products>
<product>NXI</product>
</products>
</drawing></drawings>
    <applicationFiles></applicationFiles>
    <firmwareFiles><firmware display="yes">
<revisionDate>2006-04-06</revisionDate>
<categories>
<category>Central Controllers</category>
</categories>
<name>NXI Firmware</name>
<version>1.00.22</version>
<url>/assets/firmwareFiles/2101v1.00.22.kit</url>
<target>_self</target>
<fileInfo>KIT | 140.53 KB</fileInfo>
<fileDetails>Fixed error decoding IR codes containing subchannels.</fileDetails>
<releaseDate>2002-02-25</releaseDate>
<products>
<product>NXI</product>
</products>
</firmware></firmwareFiles>
    <literature></literature>
    <logosPhotos><item>
<categories>
<category>Central Controllers</category>
</categories>
<name>NXI - Front</name>
<url>/assets/logosAndPhotos/NXI-Front.png</url>
<thumbURL>/assets/logosAndPhotos/thumbnails/NXI-Front.jpg</thumbURL>
<target>_blank</target>
<fileInfo>PNG | 2.96 MB</fileInfo>
<products>
<product>NXI</product>
</products>
<priority>2</priority>
</item><item>
<categories>
<category>Central Controllers</category>
</categories>
<name>NXI - Front Open</name>
<url>/assets/logosAndPhotos/NXI-Front-Open.png</url>
<thumbURL>/assets/logosAndPhotos/thumbnails/NXI-Front-Open.jpg</thumbURL>
<target>_blank</target>
<fileInfo>PNG | 2.40 MB</fileInfo>
<products>
<product>NXI</product>
</products>
<priority>2</priority>
</item><item>
<categories>
<category>Central Controllers</category>
</categories>
<name>NXI - Rear</name>
<url>/assets/logosAndPhotos/NXI-Rear.png</url>
<thumbURL>/assets/logosAndPhotos/thumbnails/NXI-Rear.jpg</thumbURL>
<target>_blank</target>
<fileInfo>PNG | 2.12 MB</fileInfo>
<products>
<product>NXI</product>
</products>
<priority>2</priority>
</item></logosPhotos>
    <manuals><manual>
<revisionDate>2009-01-09</revisionDate>
<categories>
<category>Central Controllers</category>
</categories>
<name>Operations Reference Manual - NXI NetLinx Integrated Controller (No Master)</name>
<url>/techdocs/NXI.OperationReferenceGuide.pdf</url>
<target>_blank</target>
<releaseDate>2009-01-09</releaseDate>
<version></version>
<fileInfo>PDF  |  355 KB</fileInfo>
<products>
<product>NXI</product>
</products>
</manual><manual>
<revisionDate>2009-01-16</revisionDate>
<categories>
<category>Central Controllers</category>
</categories>
<name>Installation Guide - NXI NetLinx Integrated Controller (No Master)</name>
<url>/techdocs/NXI.InstallationGuide.pdf</url>
<target>_blank</target>
<releaseDate>2009-01-16</releaseDate>
<version>REV D</version>
<fileInfo>PDF | 139 KB</fileInfo>
<otherLanguage>
<language>fr</language>
<url>/techdocs/International Documentation/French/NXI.QuickStartGuide.93-2101.French.pdf</url>
<target>_blank</target>
</otherLanguage>
<products>
<product>NXI</product>
</products>
</manual></manuals>
    <tpFiles></tpFiles>
    <visioStencils></visioStencils>
    <presentations></presentations>
    <videos></videos>
  <deviceModules></deviceModules></assets>
  <relatedProducts>
    <product>
		<name>NXC-ME260/64</name>
      <description>NetLinx Master Ethernet Card</description>
	  	<partNumber>FG2010-64</partNumber>
      <url>NXC-ME260-64.asp</url>
      <target>_self</target>
    </product>
    <product>
	<name>NXC-NH</name>
      <description>ICSNet Hub Card</description>
	  <partNumber>FG2060</partNumber>
      <url>NXC-NH.asp</url>
      <target>_self</target>
    </product>
    <product>
	<name>NXC-HE</name>
      <description>ICSHub Expander Card</description>
	  <partNumber>FG2062</partNumber>
      <url>NXC-HE.asp</url>
      <target>_self</target>
    </product>
    <product>
	<name>NXC-COM2</name>
      <description>Dual COM Port Control Card</description>
	  <partNumber>FG2022</partNumber>
      <url>NXC-COM2.asp</url>
      <target>_self</target>
    </product>
    <product>
	<name>NXC-I/O10</name>
      <description>Input/Output Control Card</description>
	  <partNumber>FG2021</partNumber>
      <url>NXC-I-O10.asp</url>
      <target>_self</target>
    </product>
    <product>
	<name>NXC-IRS4</name>
      <description>4-Port IR/S Control Card</description>
	  <partNumber>FG2023</partNumber>
      <url>NXC-IRS4.asp</url>
      <target>_self</target>
    </product>
    <product>
	<name>NXC-REL10</name>
      <description>Relay Control Card</description>
	  <partNumber>FG2020</partNumber>
      <url>NXC-REL10.asp</url>
      <target>_self</target>
    </product>
    <product>
	<name>NXC-VAI4</name>
      <description>Voltage Output/Analog Input Control Card</description>
	  <partNumber>FG2025</partNumber>
      <url>NXC-VAI4.asp</url>
      <target>_self</target>
    </product>
    <product>
	<name>NXC-VOL4</name>
      <description>Volume Control Card</description>
	  <partNumber>FG2024</partNumber>
      <url>NXC-VOL4.asp</url>
      <target>_self</target>
    </product>
  </relatedProducts>
</product>