<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="xsl_productPage.asp?pageName=/products/NXP-CPI16.asp"?>
<product>
  <details>
    <name>NXP-CPI16</name>
    <description>NetLinx® Custom Panel Interface</description>
    <text>
<p><strong>OVERVIEW</strong><br />
The NetLinx Custom Panel Interface provides a direct ICSNet
connection to custom control panels. It’s pin-for-pin compatible
with devices that were designed for use with the AXP-CPI16 card
(designed for integration with an Axcess Control System). Two
20-pin headers provide ribbon cable wiring or direct-connect
insertion to circuit boards, providing inputs for up to 16 closures
and 16 feedback outputs for LEDs. Under software control, the
LED outputs can act as drivers to 8-segment bargraphs or as
discrete outputs for feedback. In addition, the NXC-CPI16 also
includes two quadrature inputs for mechanical or optical rotary
encoders, used to control variable levels such as volume and
lights, or lens focus and zoom.</p>

<p><strong>COMMON APPLICATION</strong><br />
The NXP-CPI16 is a versatile, useful device for both custom panel
and contact-closure applications.</p>

<p><strong>FEATURES</strong>
      <ul>
        <li>Integrates custom panels with 16 closure inputs and 16 LED
outputs; pin-for-pin compatible with panels designed for
AXP-CPI16</li>
        <li>Operates as a low-cost closure interface</li>
        <li>Acts as a driver for up to two 8-segment LED bargraphs; each
bargraph uses eight of the 16 LED outputs</li>
        <li>Allows precision digital control of up to two levels from
quadrature inputs</li>
        <li>Accepts mechanical or optical rotary encoders</li>
        <li>Offers programmable level response, provides software-driven
performance adjustment and switchable coarse/fine level control</li>
      </ul>
	  </p>
</text>
<tabSections>
<section name="Specifications">
<text>
<p><strong>SPECIFICATIONS</strong></p>
<p><strong>DIMENSIONS (HWD)</strong><br />
2 3/4” x 1 7/8” x 1 3/8” (7.0 cm x 4.7 cm x 3.6 cm)</p>
      
<p><strong>WEIGHT</strong>
      <ul>
        <li>Device: 8.10 oz (229.6 g)</li>
        <li>Total Shipping: 1 lb (453.6 g)</li>
      </ul>
	  </p>
<p><strong>POWER</strong>
12 VDC; maximum draw of 300 mA</p>

<p><strong>INPUT CONNECTORS</strong>
      <ul>
        <li>Indicator power: Two-pin 3.5 mm captive wire</li>
        <li>I/O Headers: Two 20-pin headers, 8 I/O channels each (16 closure inputs
activated with GND or TTL Low (&#60; 0.8 V). Open collector outputs (0-28 VDC).
Inputs are sampled approximately every 10 msec</li>
        <li>Rotary Encoder inputs: 2 Quadrature inputs on a 2 x 3 header (6-pin), two
encoder inputs (4-pin) with a +5 V supply pin (supplying up to 100 mA) and
a GND pin</li>
      </ul>
	  </p>      
<p><strong>ICSNET</strong>
      <ul>
        <li>Two RJ-45 connectors for ICSNet connection ID BUTTON</li>
        <li>Generates an event from the CPI16 to allow you to assign new device numbers
using the ID mode in NetLinx Studio</li>
      </ul>
	  </p>
<p><strong>LED</strong><br />
ICSP status indicator (green)</p>

<p><strong>OPEN COLLECTOR OUTPUTS</strong><br />
16-open collector outputs, acting as a switch to ground, up to 100 mA.
Outputs can be connected to voltages ranging between 0 and + 28 V.
Each output is updated every 10 msec</p>

<p><strong>INCLUDED ACCESSORIES</strong>
      <ul>
        <li>6-pin header with 3 feet (0.914) of ribbon cable</li>
        <li>Two mating 20-pin headers, each with 3 feet of ribbon cable attached</li>
        <li>One green 2-pin 3.5 mm pitch captive wire connector for external
indicator power</li>
       </ul>
	  </p>

</text>
</section>
</tabSections> 
 <icons>
<icon>
			<iconSrc>/assets/coolIcons/gsa.png</iconSrc>
            <params name="GSA">
          <div>
            <p><strong>GSA</strong></p>                     
           <p>This product has been approved by the U.S. Government’s General Services Administration to be specified for use in government installations.</p>         
          </div>
        </params>
		</icon>	
</icons>
    <graphics>
      <thumbnail>NXP-CPI16</thumbnail>
    </graphics>
    <breadcrumbs>
      <crumb>
        <name>Products</name>
        <url>default.asp</url>
      </crumb>
      <crumb>
        <name>Keypads</name>
        <url>categoryKeypads.asp</url>
      </crumb>
      <crumb>
        <name>NXP-CPI16</name>
        <url>NXP-CPI16.asp</url>
      </crumb>
    </breadcrumbs>
    <FGInfo>
      <FG>
        <name>FG2410</name>
        <description>NetLinx Custom Panel Interface</description>
      </FG>
    </FGInfo>
  </details>
  <assets>
    <datasheets><datasheet>
<revisionDate>2006-12-18</revisionDate>
<categories>
<category>Central Controllers</category>
</categories>
<name>NXP-CPI16 NetLinx Custom Panel Interface</name>
<url>/techdocs/datasheets/NXP-CPI16.Datasheet.pdf</url>
<target>_blank</target>
<fileInfo>PDF  |  168 KB</fileInfo>
<products>
<product>NXP-CPI16</product>
</products>
</datasheet></datasheets>
    <aespecs></aespecs>
    <whitePapers></whitePapers>
    <drawings><drawing>
<categories>
<category>Pictorial (95) Drawings</category>
</categories>
<name>NXP-CPI16 NetLinx Custom Panel Interface</name>
<file>
<url>/techdocs/95241001.pdf</url>
<target>_blank</target>
<fileInfo>PDF</fileInfo>
</file>
<file>
<url>/techdocs/endwgs/95241001.dxf</url>
<target>_blank</target>
<fileInfo>DXF</fileInfo>
</file>
<products>
<product>NXP-CPI16</product>
</products>
</drawing></drawings>
    <applicationFiles></applicationFiles>
    <firmwareFiles></firmwareFiles>
    <literature></literature>
    <logosPhotos><item>
<categories>
<category>Keypads</category>
</categories>
<name>NXP-CPI16</name>
<url>/assets/logosAndPhotos/NXP-CPI16.png</url>
<thumbURL>/assets/logosAndPhotos/thumbnails/NXP-CPI16.jpg</thumbURL>
<target>_blank</target>
<fileInfo>PNG | 2.36 MB</fileInfo>
<products>
<product>NXP-CPI16</product>
</products>
<priority>3</priority>
</item></logosPhotos>
    <manuals><manual>
<revisionDate>2009-01-16</revisionDate>
<categories>
<category>Keypads</category>
</categories>
<name>Operation/Reference Guide - NXP-CPI16 NetLinx Custom Panel Interface</name>
<url>/techdocs/NXP-CPI16.OperationReferenceGuide.pdf</url>
<target>_blank</target>
<releaseDate>2009-01-16</releaseDate>
<version>REV B</version>
<fileInfo>PDF  |  288 KB</fileInfo>
<products>
<product>NXP-CPI16</product>
</products>
</manual></manuals>
    <tpFiles></tpFiles>
    <visioStencils></visioStencils>
    <presentations></presentations>
    <videos></videos>
  <deviceModules></deviceModules></assets>
  <relatedProducts></relatedProducts>
</product>
