Application Files

Select an application category from the list below to see all the downloadable files and their descriptions in that category. Go to Archived Applications Files to find previous versions of applications.

AMX USB LAN

Install this application driver for TPDesign4 and NetLinx Studio for support of direct connection to Modero VG Series panels via USB.

New Features:

  • Supports Mio R-4 remotes


EXE | 2.83 MB | v. 2.3.3.6 | 2007-05-22
NetLinx Studio
TPDesign
Cafe Duet (use WebUpdate to download)

Duet is the unique and powerful dual-interpreter environment for programming NetLinx control systems. Program the system in NetLinx or Java or a little of both. Simplify your programming world!

Central Controller firmware 3.41.422 or better is a pre-requisite. For this release, the Device SDK was modified to include the following additional devices:

  • Functionality fix for PASSBACK module-level behavior
  • Fixed echo-effect on SNAPI commands (e.g: CAMERAPRESETPROPERTIES issue)
  • Fixed parsing of Bundle-Version and Duet-Revision


106 MB | v. 1.8.85 | 2009-10-07
NDT-CAFEDUET
FileTransfer 2

NOTE: You must have the latest firmware versions for your NetLinx masters before you can use the device feature listed above. Versions greater than 387 are recommended. Unpredictable results may occur if your master firmware has not been updated to the proper version.

New Features:

  • File transfer support for devices that have STANDBY and AWAKE states (MVP-5200i)

EXE | 40.7 MB | v. 1.6.150 | 2008-12-12
FileTransfer2
G4 PanelBuilder

G4 PanelBuilder is a Windows application that offers accelerated development of AMX G4 user interface pages using G4 PanelBuilder Templates (.TPT) available from AMX or designed by the dealer.

New Features: Support for NXD-CV10, NXT-CV10, and NXT-CV10/PB panels.


EXE | 16.97 MB | v. 1.1.1 Build 101 | 2005-06-21
G4 PanelBuilder
G4 PanelPreview

Software and Hardware Requirements:

To install G4 Panel Preview, you must have the following software installed on your computer:

  • Microsoft Windows 7 or Windows 8
  • Direct3D v9
  • Operating System Languages: English, Spanish, French, German

Minimum hardware requirements:

  • Pentium 233 MHZ processor (minimum requirement); 300 MHZ or faster recommended
  • 10 MB of free disk space (minimum requirement); 20 MB recommended
  • 128 MB of installed memory (RAM).
  • Minimum (VGA) screen resolution of 800x600

New Features:

  • Added support for Modero-X touch panels
  • Added page-flip transitions
  • Added sub-page views
  • Added support for complex-script language rendering
  • Added support for gestures
  • External buttons will be displayed in a separate, scalable window (except for Mio-Modero R-4 projects)
  • User Preference: Show External Buttons at Startup
  • User Preference: Scale Oversized Panels on Startup
  • Will install and run on Windows 7/Windows 8

ZIP | 55.2 MB | v. 2.1.78 | 2013-04-15
G4 PanelPreview
G4 Support Files

New Features:

New panel devices: Modero-S Series MST-431 & MSD-431

  • 4.3 inch color wall-mount and table-top touch panels with intercom
  • 480 x 272 resolution
  • Supports landscape resolution only
  • Resistive touch overlay
  • Sub-Page View buttons
  • Animated Page Transitions

New panel devices: Modero-S Series MST-701 & MSD-701

  • 7.1 inch color wall-mount and table-top touch panels with intercom
  • 1024 x 600 resolution
  • Supports landscape resolution only
  • Resistive touch overlay
  • Sub-Page View buttons
  • Animated Page Transitions

New panel devices: Modero-S Series MST-1001 & MSD-1001

  • 10 inch color wall-mount and table-top touch panels with intercom
  • 1280 x 800 resolution
  • Supports landscape resolution only
  • Resistive touch overlay
  • Sub-Page View buttons
  • Animated Page Transitions

Known Issues

MVP-5150/5200 Firmware Update Requirements
Please note that features added to these panel-types as of G4SF Release 3.1.34 will require a Device Firmware upgrade to version 2.87.1 or greater.

TPI-PRO/TPI-PRO-DVI Resolutions
The newest resolution, 1280 x 800 @ 60Hz, fill require a Device Firmware upgrade to version 2.6.36 or greater.


ZIP | 38.6 MB | v. 3.3.53 | 2013-06-11
MIO R-4
MSD-1001
MSD-431
MSD-701
MST-1001
MST-431
MST-701
MVP-5100
MVP-5150
MVP-5200i
MVP-7500
MVP-8400
MVP-8400i
MXD-1000
MXD-1000-NC
MXD-1900L-PAN
MXD-1900L-PAN-NC
MXD-2000XL-PAN
MXD-2000XL-PAN-NC
MXD-430
MXD-700
MXD-700-NC
MXT-1000
MXT-1000-NC
MXT-1900L-PAN
MXT-1900L-PAN-NC
MXT-2000XL-PAN
MXT-2000XL-PAN-NC
MXT-2001-PAN
MXT-700
MXT-700-NC
NetLinx Studio
NSS-VA
NXD-1000Vi
NXD-1200V
NXD-1200VG RGB Kit
NXD-1200VG Video Kit
NXD-1500VG RGB Kit
NXD-1500VG Video Kit
NXD-1700VG RGB Kit
NXD-1700VG Video Kit
NXD-430
NXD-435
NXD-500i
NXD-500iW
NXD-700i
NXD-700Vi
NXD-CV10
NXD-CV5
NXD-CV7
NXP-PLV
NXT-1200V
NXT-1200VG RGB Kit
NXT-1200VG Video Kit
NXT-1500VG RGB Kit
NXT-1500VG Video Kit
NXT-1700VG RGB Kit
NXT-1700VG Video Kit
NXT-CA7
NXT-CV10
NXT-CV7
NXV-300
TPDesign
TPI-PRO
TPI-PRO-DVI
G5 Support Files

New panel devices: Modero-X G5 Series MXT-701 & MXD-701

  • 7.1 inch color wall-mount and table-top touch panels with intercom
  • 1024 x 600 resolution (600 x 1024 portrait)
  • Portrait resolution available on wall-mount only

New panel devices: Modero-X G5 Series MXT-1001 & MXD-1001

  • 10 inch color wall-mount and table-top touch panels with intercom
  • 1280 x 800 resolution (800 x 1280 portrait)
  • Portrait resolution available on wall-mount only

New panel devices: Modero-X G5 Series MXT-1901-PAN & MXD-1901-PAN

  • 19 inch color wall-mount and table-top touch panels with intercom
  • 1920 x 530 resolution (530 x 1920 portrait)
  • Portrait resolution available on wall-mount only

New panel devices: Modero-X G5 Series MXT-2001-PAN & MXD-2001-PAN

  • 20 inch color wall-mount and table-top touch panels with intercom
  • 1920 x 800 resolution (800 x 1920 portrait)
  • Portrait resolution available on wall-mount only

Supported Applications

  • AccuWeather Quick
  • ADV PDF Viewer Pro
  • Browser
  • Calculator
  • Calendar
  • Contacts
  • Currency Converter
  • Dropbox
  • Email
  • FileBrowser
  • Gallery
  • PlanMaker Mobile
  • Presentations Mobile
  • QuickDic
  • Quote Pro
  • Skype
  • TextMaker Mobile

ZIP | 5.72 MB | v. 1.0.16 | 2014-02-17
MXD-1001
MXD-1901-PAN
MXD-2001-PAN
MXD-701
MXT-1001
MXT-1901-PAN
MXT-2001-PAN
MXT-701
i!-Database Plus
integration! Solutions release
EXE | 3.47 MB | v. 1.4.23 | 2005-01-31
i!-Database Plus
IREdit 1.3 Build 79

IREdit provides the ability to capture and edit IR hand control files (.IRL, .IRV, or IR information contained within a .IRN database file) for use on Axcess and NetLinx platforms.

New Features: IREdit now includes additional data in the AMX IR database to support IR devices in VisualArchitect. Visual Architect can read the AMX IR database and add IR devices to the list of available devices that can be added to the system. The VisualArchitect data is also updated using the Web Update feature when a new AMX IR database version is released.


EXE | 5.65 MB | v. 1.3 | 2006-03-28
IREdit
IREdit - Database

After installing the initial database, please update through the IREdit IR Update utility. AMX is constantly adding IR codes to the database. The database can be updated via AMX IR Update. Within the IREdit application, go to Help > AMX IR Update to launch the IR Update Wizard Dialog.


EXE | 15 MB | v. 1.0.16
IREdit
IREdit - System Files
This file will install all of the Windows components necessary to install and run IREdit v1.1. NOTE: IREdit System Files must be installed prior to installing the IREdit application.
EXE | 37.98 MB | v. 1.1 | 2003-12-05
IREdit
KeypadBuilder
New Features:
  • Updated application to work with Windows Vista operating system

EXE | 38.8 MB | v. 2.3.0.93 | 2009-07-29
KeypadBuilder
NetLinx Diagnostics Installation
Version 1.00 build # 14 The NetLinx Diagnostics Application provides the ability to send/receive required ICSP messages to/from a NetLinx controller via serial or tcp/ip connection(s). It is used primarily for troubleshooting NetLinx controllers and devices attached to these controllers.
EXE | 1.29 MB
NetLinx Studio 4
  • Added support for the new NX-x200 series masters that include IPv6 and USB connectivity
  • Added support for the G5 Touch Panel Design files (*.tp5)
  • Added support for the Device Driver files (.xdd)
  • Ability to transfer "Other" files assigned to the APW to a user defined directory on the master
  • Updated the "Listen for Masters" dialog (shows the master ID, Host Name and MAC Address)
  • Updated the "Communications Dialog" to handle the support for USB and IPv6 connectivity
  • Added the "Custom Events" option to the Asynchronous Notifications message stream
  • Added support for Master Certificate and Key Files: (.pem, .key, .p12, and .crt type files)
  • Ability to change font/point size for the following display windows:
    • Output Status
    • Notifications
    • Diagnostics
    • Terminal
    • TELNET
  • Ability to launch a TELNET window from the System folder without having to activate an Online Tree
  • Added a "Preferences" button to the "File Transfer" dialog
  • New Application Color Schemes are now available (visit the "General Tab" of the Preferences dialog)
  • Updated the NLRC.EXE program (NetLinx Compiler Command Line Program) that will now accept a configuration file for compilation. Please visit the C:\Program Files (x86)\Common Files\AMXShare\RunNetLinxCompiler directory for more information
  • Corrected the problem of exporting AXS/AXI files to an AXW file when the user selected to "Exclude" these files from the export
  • Reactivated the "Port Status" menu option within the Online Tree
  • Corrected the problem of the Device Mapping dialog not populating correctly when the AXS file had DEFINE_DEVICE keyword is in mixed case
  • Corrected the problem of not being able to open the temporary TELNET view file when the user selects to start a NetLinx Studio TELNET session
  • Corrected the problem of the NetLinx Compiler not reporting the correct File Name/Line number when showing #WARNING directives in the Output Status bar
  • The following features will no longer be supported with NetLinx Studio V4.0:
    • File Transfers for G3 Panels (TPD files)
    • File Transfers for Mio Keypads (KPD Files)
    • File Transfers to Axcent Masters (TOK Files)
    • The Axcess Compiler will be not be installed

ZIP | 80.5 MB | v. 4.0.1017 | 2014-06-27
NetLinx Studio
NetLinx Studio 3

What's New

  • BUG FIX - Corrected the problem of not being able to bind/unbind devices from the Online tree when connected to DGX devices that have upgraded firmware.
  • BUG FIX - Corrected the problem of passing an incorrect IP address to the G5 panels during a firmware KIT file transfer via the internal HTTP server.

ZIP | 91.43 MB | v. 3.5.960 | 2014-04-24
NetLinx Studio
NetLinx Studio SNAPI 1.15 Update
New Features:
  • High Performance updates requiring Firmware 3.41.422 or better
  • Functionality fix for PASSBACK module-level behavior
  • Fixed echo-effect on SNAPI commands
  • Fixed parsing of Bundle-Version and Duet-Revision

EXE | 3.72 MB | v. 1.15.230 | 2009-10-07
NetLinx Studio
TPDesign5

New with this release

  • App Windows: Added VNC Client support
  • Added support for the following Page Flip Animations
    • slide
    • slide bounce
    • fade
    • door fade
    • center door fade
    • zoom in
    • zoom out
    • spin in
    • spin out
  • Added support for Unicode text for Command and String outputs
  • Restored Active-Centering, Drag, and Drag-Centering level functions
  • Restored Dynamic Re-ordering to Sub-Page View buttons
  • App Windows: Added URI parameter to Browser app
  • Updated project format - TPD5 v1.0 projects will be updated to the v1.1 format when opened in TPD5 1.1
  • G4Utility - Updated to convert TPD4 projects to the TPD5 v1.1 format
  • G4Utility - Will migrate the supported G5 page flip animations. Non-supported animations will be reverted to standard page flips.
  • Updated and revised Help content
  • Bundles updated G5 Support Files v1.1 install

ZIP | 38.1 MB | v. 1.1.38 | 2014-07-09
MXD-1001
MXD-1901-PAN
MXD-2001-PAN
MXD-701
MXT-1001
MXT-1901-PAN
MXT-2001-PAN
MXT-701
TPDesign5
TPDesign4

Features

New panel devices: Modero X Series

MXD-430

  • 4.3 inch color widescreen wall-mount touch panel with intercom
  • 480 x 800 resolution (portrait only)
  • supports both single- and two-finger gestures

Video Graphics Fill: (Modero X Series only)

  • Added new source option: MXA-MPL

NOTE: Enabling MXA-MPL source will require panel firmware v2.103.x or greater

Sub-Page View: (Modero X Series only)

  • Added scrollbar indicator properties
    • ScrollBar toggle enable/disable
    • Scrollbar Offset position relative to right/bottom border

NOTE: Sub-Page View scrollbar will require panel firmware v2.103.x or greater

Page Flip Animations (Modero-X Series only)

  • Added twelve new animated transitions for Modero-X Series panels:
    • zoom in
    • zoom out
    • implode
    • explode
    • spin in
    • spin out
    • flip card
    • tumble
    • slats
    • squish
    • wipe
    • waves

NOTE: New transitions will require panel firmware v2.103.x or greater.

Fonts:

  • Fixed Space character issue with font amx_icons.ttf
  • Fixed issue with non-referenced fonts remaining in .TP4 project file (For more details, refer to the "Known Issues" section below.)

Function Map Tree: Added ability to expand/collapse ports

Panel Reports: Added Sub-Page Sets and Sub-Page View Buttons

AMX USB Driver Information for USB Enabled G4 Panels

NOTE: The AMX USB driver is no longer bundled in the installations of TPDesign4 or other AMX software applications. This change is effective with the release of TPDesign4 version 2.7.

To download the latest AMX USB driver, please visit the AMX website. (Search on keyword "AMX USBLAN".)

After installation of the AMX USB Driver, please follow the steps below to ensure a valid USB connection to the G4 panels:

  1. Power up the Panel without the USB cable connected to the panel.
  2. Plug in the USB cable into the G4 panel.
  3. You should see an USB icon show up in the System Tray.
  4. Double click on the icon to bring up the list of USB devices you should see the "AMX USB LAN LINK"" device in the list).
  5. If the "Install Driver" dialog doesn't appear automatically, select the "Properties" button and then the "Update Driver" button.
  6. When the Install Driver dialog does appear, click on the Next buttons, accepting all the default prompts.
  7. The OS will complain about the fact that the driver you are installing/updating does not have a digital signature. This is acceptable, so select to continue the installation.
  8. After installation is complete, you are ready to connect to the USB port of the G4 panel. This is done via the Virtual NetLinx Master connection in the Transfer->Connect dialog.

Known Issues - This section contains the identified issues that this version is shipping of the product contains

  • Most languages can be entered into the state via Windows language packs. However, some languages are not supported by code-pages. These languages will display ??? for characters entered via the keyboard, even if the selected font supports the language. However, text in these languages can still be pasted via the clipboard.
  • This TPDesign4 release adds support for list box buttons as well as marquee text and the new page-flip "forget" acction for use with the R-4 remote device. The R-4 device does support these new features. However, these features are also available for the other existing panel types, but are as yet not supported in the existing firmware of those devices.
  • If TPDesign4 is minimized when a transfer completes, the docking location of the toolbars and control bars will be lost.
  • On some Windows NT operating systems you may receive the following error upon launching the application... "Entry Point Not Found. The procedure entry point __lc_collate_cp could not be located in the dynamic link library MSVCRT.dll." If this should occur, rebooting the machine should solve the issue, and this should only need to be performed once.
  • Font Replacement
    Starting with version 2.7, TPDesign4 will replace all instances of non-supported fonts with an appropriate replacement font when a panel project is opened. The panel project will be marked as modified at this point. The unsupported fonts, along with the corresponding replacement font, are listed below:
    • Unsupported Font: AMX Icon 2 Normal
    • Replacement Font: AMX Icon 3
  • Unused Fonts
    • TPDesign4 users may occasionaly encounter the situation where fonts no longer used in the project continue to be retained in the project and sent to the touch panel. A modification has been added to TPD4 v3.3 Build 670 and greater to resolve this.
    • This process requires three distinct actions to be taken by the user.
      • Step 1 - Select "Verify Function Maps" from the Panel menu. This will iterate through the entire project and rebuild all of the font references in addition to the function maps.
      • Step 2 - Use the "Find & Replace" feature from the Edit menu to replace all references to the font to be removed with a new font selection. This is located down in the "States" section of properties.
        This must be repeated for each font descriptor listed in the "Search Criteria" (left) side of the dialog for the "State-Font" property.
        NOTE: Be sure to specify "Entire Panel" for scope.
        When all references have been replaced, the font should no longer appear in the list of font descriptors provided in the "Search Criteria".
      • Step 3 - Save the project. All unreferenced fonts should be dropped from the project when the project is saved.

NOTE: The "AMX Icon 2 Normal" font should be removed from the collection of Windows registered fonts, as it can possibly create conflicts with the font "AMX Icon 2". This can be accomplished by going to the Fonts page in Windows Control Panel and deleting the entry for "AMX Icon 2 Normal (True Type)".


ZIP | 70.59 MB | v. 3.3.674 | 2012-10-18
MIO R-4
MVP-5100
MVP-5150
MVP-5200i
MVP-7500
MVP-8400
MVP-8400i
MXD-1000
MXD-1000-NC
MXD-1900L-PAN
MXD-1900L-PAN-NC
MXD-2000XL-PAN
MXD-2000XL-PAN-NC
MXD-430
MXD-700
MXD-700-NC
MXT-1000
MXT-1000-NC
MXT-1900L-PAN
MXT-1900L-PAN-NC
MXT-2000XL-PAN
MXT-2000XL-PAN-NC
MXT-2001-PAN
MXT-700
MXT-700-NC
NXD-1000Vi
NXD-1200V
NXD-1200VG RGB Kit
NXD-1200VG Video Kit
NXD-1500VG RGB Kit
NXD-1500VG Video Kit
NXD-1700VG RGB Kit
NXD-1700VG Video Kit
NXD-430
NXD-435
NXD-500i
NXD-500iW
NXD-700i
NXD-700Vi
NXD-CV10
NXD-CV5
NXD-CV7
NXP-PLV
NXT-1200V
NXT-1200VG RGB Kit
NXT-1200VG Video Kit
NXT-1500VG RGB Kit
NXT-1500VG Video Kit
NXT-1700VG RGB Kit
NXT-1700VG Video Kit
NXT-CA7
NXT-CV10
NXT-CV7
NXV-300
TPDesign
TPI-PRO
TPI-PRO-DVI
VisualArchitect (Available on DVD or WebUpdate)

VisualArchitect is a comprehensive system design platform that increases the productivity and efficiency of your organization. VisualArchitect simplifies generation of all the programming, touch panel files, IR codes and system documentation for an integrated control system. This software is free to Authorized AMX Dealers and Independent Programmers and is available thru your AMX sales representative. For Domestic Dealers, place an order for NSS-VA, FG3002-21, to receive an installation disc with license key. International dealers should order NSS-VA-INTL, FG3002-21INTL, and contact your regional distributor for the disc, license key and MSRP pricing file in your local currency.

New In Version 1.4.3:

  • Background image skins
  • 'REPEAT' parameter for a 'HOLD' Event in Code Builder
  • Support for new AMX devices
    • User Interfaces
      • MVP-9000i, NXD-430, NXD-435 / 435P,NXV-300
      • ENV-VST-C / i!-Weather ViewStat Thermostat and software
      • Novara AxLink ControlPads
    • Signal Management
      • UDM-0808-SIG Universal Distribution Matrix
      • AVX-400 Presentation Switcher
      • AVS-OP-0808
      • HDMI-UTPRO-0808 HDMI Matrix Switchers
    • Lighting
      • Radia RE-DC 120/240/277 Radia Eclipse Control Cards
    • Software
      • NSS-PFRAME PictureFrame, i!-Weather

Prerequisite Software
The following software packages must be installed on the target system before VisualArchitect can be installed:
All Supported Operating Systems:

  • Microsoft .NET Framework 2.0 (Available through Windows Update)
  • Windows XP:
    • Service Pack 3 (Available through Windows Update)
  • Windows 7
  • Microsoft MDAC 2.7 SP 1 or later (Available at: http://msdn.microsoft.com/data/ref/mdac/downloads/). It is recommended that you also re-run Windows Update after installing MDAC to apply any patches that have been provided by Microsoft.

Companion Software Versions

  • FileTransfer 2, 1.6 build 150 or higher, is required for system file transfer support in VisualArchitect (automatically installed with VisualArchitect).
  • AMX USBLAN driver, 2.2.1.5 or higher, is required for transfer of R-4 remotes.
  • TPDesign4 3.0 or higher is required to create or edit VisualArchitect touch panel templates, or to edit touch panel projects generated by VisualArchitect.
  • KeypadBuilder 2.1 or higher is required to edit keypad projects generated by VisualArchitect.
  • NetLinx Studio 2.5, build 163 or higher, is required to open APW (NetLinx Studio workspace) files generated by VisualArchitect.
  • Cafe Duet 1.8 or higher is required to create or edit Duet modules for use with VisualArchitect.
  • IREdit 1.3 or higher is required to receive AMX IR Database updates containing IR control meta-data.

Known Issues
If a version of NetLinx Studio prior to 2.4 build 129 is installed AFTER VisualArchitect, the SNAPI.axi file will be overwritten with an older version that will cause compilation problems. Please ensure that the SNAPI.axi file installed in C:\Program Files\Common Files\AMXShare\AXIs (or equivalent local path) is v1.6.1. If not, please re-install VisualArchitect.


Available on DVD or WebUpdate | v. 1.4.3 | 2010-09-20
NSS-VA
Feedback | Gear Store | Site Map | Terms & Conditions | Warranty