All AMX Hot Fix Files are designed to provide immediate support for specific, isolated, conditional issues. Hot Fix Files are not to be considered standard firmware updates. Hot Fix Files complete a shorter, less arduous product verification process in an effort to get known fixes out into the field as quick as possible. Official Download Update Firmware files that have undergone additional testing before being fully approved for wide spread release will be forthcoming and should be used if time permits.
AVX-400 Twisted Pair Presentation Switcher Firmware v.2.5 Hot Fix (Available from AMX Technical Support)

Changes in this release:
Fixed: Power status and lamp hours updates with projectors that use binary protocol


2013-06-26
AVX-400
DXLink Transmitter Firmware v.1.6.32 Hot Fix (Available from AMX Technical Support)

Changes in this release:
Added use of actual DVI only edid mode setting. To turn dvi mode on, type "dvi on" from the telnet interface. "dvi off" will turn it off, and "dvi" will give the status. After changing the status of the dvi mode, a reboot is necessary "This mode will pass the DVI edid only to the source, and not include the extended edid, but only when the sink from the RX is actually dvi. The mode should not affect hdmi sinks"

Fixes applicable to all devices:

  • Fixed a video offset issue when viewing NTSC video.
  • Implemented method to get BER data from remote Valens connection
  • Improve robustness of video detection for noisy digital sources
  • Added commands to force freeRun modes for video debugging
  • Video monitor addition to ensure video is evaluated and setup properly
  • Improved video recovery when video is not detected properly
  • Fixed a memory leak in ICSP that could cuase a lockup
  • Includes VIDIN_AUTO_SELECT-ANALOG. Allows auto select to prioritize analog over digital signals.
  • Includes watchdog. To turn the watchdog on, type "wd on" from the telnet interface. "wd off" will turn it off, and "wd" will give the status. After changing the status of the watchdog, a reboot is necessary
  • Includes low memory monitoring in the watchdog. If low memory is detected, the device will reboot.
  • Includes ICSP timeout monitoring in the watchdog. If the device falls offline from the Master for more than 5 minutes, the device will reboot.
  • Fixed a problem that would display a pink screen on the output display when in a point to point setup

Known Issues:
ANALOG mode is limited to detecting correct analog format.


2014-12-16
AVB-TX-HDMI-DXLINK
DX-TX
DX-TX-DWP
DX-TX-WP
DXLink HDMI Receiver Module Firmware v.1.9.53 Hot Fix (Available from AMX Technical Support)

Prerequisites:

  • DXLink RX v1.9.10 (or later) should be loaded on the DXLink Receiver prior to upgrade
  • DXLink TX v1.6.7 (or later) should be loaded on the DXLink Transmitters to get the most benefit from this RX version
  • Enova DGX enclosures should at least have the following:
    • DGX 8/16/32 (NI Master) v4.2.395 & DGX kit 2.0.0.12
    • DGX 8/16/32/32 (NX Master) v1.2.312 & DGX kit 2.0.0.12
  • Enova DVX 315X and 215X should at least have the following:
    • Master v4.8.316
    • Switcher Firmware v1.6.31
  • NetLinx Studio V3.4 (4.0 if using NX master)

Features added in this release:
No new features

  • Previously released in v1.9.52
    • Added a watchdog for point to point setups. In a telnet session, type "wdp2p on x.x.x.x" to enable. The x.x.x.x is the ip address of the opposite device. To disable, in a telnet session type "wdp2p off". A reboot is required after enabling or disabling the state for it to take effect. Leave the RX and MFTX in static ip mode. Once the devices ping each other the watchdog will be armed. If they fail to ping each other for 1 minute the watchdog will fire.
  • Previously released in v1.9.49
    • Added an offline recovery mechanism if a master connection is expected. In a telnet session, type "wdurlsocket on" to enable or "wdurlsocket off" to disable this feature. WARNING! - Do not use this feature if the DX-RX is not configured to connect to a Master.
  • Previously released in v1.9.38
    • Added manual resolution 1920x1080p@50Hz to supported res/ref list (VIDOUT_RES_REF-1920x1080p,50)
    • Added manual resolution 1280x800@120Hz to supported res/ref list (VIDOUT_RES_REF-1280x800,120)

Fixes in this release:
Fixed a video issue where no video would be sent to certain sink devices (i.e. Polycom HDX8000)

Previously released in v1.9.49

ONLINE

  • Fixed issue where an DX-RX could generate multiple online/offline events during bootup of the system. This seemed to occur more frequently when the DX-RX's are configured with static IP address.
  • Improved the AMX master connection to reduce the number of offline events.
  • Fixed an issue with the TCP 3-way handshake process. This issue also caused offline events.

VIDEO

  • Fixed black screen issue seen with some Dell laptops as the source in point to point setups after unplugging the HDMI cable.
  • == Previously released in v1.9.38 ==
  • Hardened upstream video detection and monitoring
  • Improved HDCP authentication to prevent Orange Screen on certain HDCP compliant monitors
  • Corrected VIC (Video Info Code) reporting when manual CEA resolutions are used
  • Fixed video flicker issue due to audio changes from certain upstream devices (i.e. DGX SC Fiber TX)

AUDIO (RX.e and RX.c)

  • Corrected detection issues of various Surround Sound (Dolby/DTS) and HBR (High Bit Rate) Audio formats (Dolby TrueHD/DTS-HD Master Audio)
  • NOTE: HBR audio REQUIRES Hi-Def VIDEO with a pixel clock of 127MHz or higher, in order to effectively pass HBR content (i.e. 1280x720p,60 / 1920x1080p,60 / etc.)

Notable Points:

  • If a send command "FACTORYAV" or telnet "RESET FACTORY" is sent, a reboot of the RX will be required.
  • PLEASE READ the documentation in regard to the DIP switches located on the bottom of the Tx/Rx modules before attempting to connect to the network
  • The RX uses a solid ORANGE screen to indicate an HDCP authentication failure with the connected device
  • If using a hostname in the USB_HID_ROUTE command, the hostname length is limited to 50 characters

Programming Information

UPGRADING

Important–Due to a HWID change, this kit will FAIL on the first attempt of the kit transfer IF upgrading from firmware earlier than v1.9.32

  1. Transfer kit v1.9.53 to the RX. If upgrading from a version earlier than 1.9.32, it will abort: "Transfer Aborted Unsupported file type." If this happens, then proceed to step 2
  2. Reboot the RX (via telnet or power cycle) then check the firmware versions in the Online Tree:
    • g. 07001 - DXLINK-HDMI-RX.e (v1.9.53)
    • [OID=1] - MQX (v3.62)
    • [OID=2] - DXLINK Boot (v1.9.53)
    • [OID=3] - DXLINK App (v1.9.53)
    • [OID=5] - DXLINK Link (3.0.x.x)
    • [OID=6] - DXLINK FPGA (1.0.0.6)
  3. If the FPGA is still not up to date, then transfer kit v1.9.53 again to completele the transfer of the final component. If the FW is up to date then no other kit transfers are required.

DOWNGRADING

  • Also due to the HWID change, RX's with a factory firmware image of v1.9.32 or later will not be able to downgrade to versions earlier than v1.9.32. The loaded fw images can be seen in a telnet session to the RX by typing: fwimages
  • Example of RX that can be downgraded below 1.9.32: >fwimages
  • Available Firmware Images
  • Slot Boot App
    • 0 v1.9.17 v1.9.17 //0 is the factory image
    • 1 v1.9.38 v1.9.38 //upgraded to .38
    • *2 v1.9.28 v1.9.28 //then downgraded to .28
    • * - slot to use at next boot
  • Booted from slot 2 - v1.9.28 v1.9.28

2015-11-11
AVB-RX-DXLINK-HDMI
DX-RX
Enova DGX 8/16/32 NI Master Firmware v.4.2.397 Hot Fix (Available from AMX Technical Support)

Changes in this release:

  • Corrected problem with limited / no network communication following a power outage
  • Corrected problem with socket communication timeout
  • Corrected AMX Processors Vulnerable to SSLv3 POODLE by only supporting TLSv1.0 on HTTPS port
  • Corrected problem with no scroll bars on Touch Panel remote access via internet browser
  • Removed debugging account to prevent security vulnerability


2016-01-22
AVS-ENOVADGX16-ENC
AVS-ENOVADGX32-ENC
AVS-ENOVADGX32-ENC-A
AVS-ENOVADGX8-ENC
ICSLan Device Control Boxes Firmware v1.0.62 Hot Fix (Available from AMX Technical Support)

Changes in this release:

  • Fixed a memory leak problem that could occur in ICSP message handling
  • Updated IR transmit to support alternating IR patterns


2015-04-20
EXB-COM2
EXB-IO8
EXB-IRS4
EXB-MP1
EXB-REL8
Modero 5" Intercom Touch Panel Firmware v.2.86.23 Hot Fix (Available from AMX Technical Support)

Changes in this release:

  • Fixed the scenario where the graphics would not update on the display
  • Fixed the scenario where the panel drops offline to the AMX master and does not recover the connection

2013-09-30
NXD-500i
NXD-500iW
Massio ControlPads Master Firmware v.1.4.66 Hot Fix (Available from AMX Technical Support)

Changes in this release:

  • Fixed IP_MC_SERVER_OPEN so that it supports connections on the ICSLan network.
  • Fixed SSH_CLIENT_OPEN so it properly creates an SSH connection to the specified server.

Known Issues:
The Manage Devices tab is not implemented, it will be added in a future release.


2016-01-15
MCP-106
MCP-108
Modero MVP-5150/MVP-5200i Touch Panel Firmware v.2.87.35 Hot Fix (Available from AMX Technical Support)

Changes in this release:

  • Fixed the scenario where the graphics would not update on the display
  • Fixed the scenario where the panel drops offline to the AMX master and does not recover the connection

2013-09-30
MVP-5150
MVP-5200i
Modero MVP-8400 and MVP-8400i Touch Panel Firmware v 2.86.71 Hot Fix (Available from AMX Technical Support)

Changes in this release:

  • Wireless signal level updates on user pages
  • Fixed RMF command to support more than 150 characters

2012-09-05
MVP-8400
MVP-8400i
Modero 7" Touch Panels Firmware v.2.86.40 Hot Fix (Available from AMX Technical Support)

Changes in this release:

  • Fixed an issue where the panel could fall off line or reboot due to an issue with the watchdog monitoring system
  • Fixed an issue where the Ethernet driver could crash in high traffic environments


2015-09-11
NXD-CV7
NXT-CV7
Modero 10" CV Touch Panels Firmware v.2.86.41 Hot Fix (Available from AMX Technical Support)

Changes in this release:

  • Fixed an issue where the panel could repeatedly fall off line or reboot due to an issue with the watchdog monitoring system. The watchdog is fixed and updated with a logging feature that will persist over reboots for future analysis.
  • Fixed an issue where the Ethernet driver could crash in high traffic environments
  • Fixed issue with bar graphs set using the ^GLH & ^GLL send commands and the handling of negative values.


2015-09-28
NXD-CV10
NXT-CV10
Modero NXD-430 and NXD-435 Touch Panel Firmware v.2.86.15 Hot Fix (Available from AMX Technical Support)

Changes in this release:

  • Fixed the scenario where the graphics would not update on the display
  • Fixed the scenario where the panel drops offline to the AMX master and does not recover the connection

2013-09-30
NXD-430
NXD-435
Modero NXD-700i / NXT-CA7 v.2.92.17 Hot Fix (Available from AMX Technical Support)

Changes in this release:

  • Fixed the scenario where the graphics would not update on the display
  • Fixed the scenario where the panel drops offline to the AMX master and does not recover the connection

2013-09-30
NXD-700i
NXT-CA7
NetLinx Duet Master Firmware (NXC-ME260/64) v. 3.60.456 Hot Fix (Available from AMX Technical Support)

Changes in this release:

  • Fixed Master-to-master issue were multiple online events were occurring for device ports greater than 1.
  • Removed debugging account to prevent security vulnerability


2016-02-02
NXC-ME260-64
NI Series Device Firmware v.1.30.9 Hot Fix (Available from AMX Technical Support)

Known Issues:
Hot Fix For NI-700, NI-900, NI-X000, NI-X100, NI-X101

NI-device side firmware Build v1.30.9 Release Notes

Prerequisites:
None.

Dependencies:
Requires master firmware 3.60.447 or later. If this NI-device firmware is loaded on an earlier version of master firmware, the integrated device (5001) will be unavailable until the master side firmware is upgraded to 3.60.447 or later.

Changes in this release:

  • Fixes Escape Sequence from not working correctly after a few minutes
  • Fixes "SET IO LINK <io>" command, no longer causes any conflicts


2012-02-24
DVX-2100HD
NI-2000
NI-2100
NI-3000
NI-3100
NI-3101-SIG
NI-4000
NI-4100
NI-700
NI-900
NI Series (NI-700 and NI-900) 32 MB Duet Master Firmware v.3.60.456 Hot Fix (Available from AMX Technical Support)

Prerequisites:

  • Master build 300 or greater. (see Programming Information)
  • Requires NI-Device firmware version of 1.30.8 or greater to fully utilize the enhancements.
  • If NI-Device version 1.30.8 or later is loaded before this master firmware version, the integrated device (5001) will be unavailable until the master side firmware is upgraded.

Changes in this release:

  • Fixed Master-to-master issue were multiple online events were occurring for device ports greater than 1.
  • Removed debugging account to prevent security vulnerability

Programming Information:
If you currently have a firmware build less than 300, to upgrade to this version (or greater) the upgrade requires the following process:

  • Download kit with build 300 (or greater) - Download of last component will fail.
  • Reboot master
  • Wait until you have connectivity to the master or you have a blinking AXLink status LED. This may take a couple of minutes.
  • Download kit with build 300 (or greater) again - Download should pass.
  • Reboot master.
  • Please wait. This will take a few minutes for file extraction and key SSH generation. When you have connectivity to the master or the AXLink LED is blinking the master is ready.

  • 2016-02-03
    NI-700
    NI-900
    NI Series (X000) Duet Master Firmware v. 3.60.456 Hot Fix (Available from AMX Technical Support)

    Changes in this release:

    • Fixed Master-to-master issue were multiple online events were occurring for device ports greater than 1.
    • Removed debugging account to prevent security vulnerability


    2016-02-03
    NI-2000
    NI-3000
    NI-4000
    NI Series (X100) Device Firmware v.1.30.10 Hot Fix (Available from AMX Technical Support)

    Dependencies:
    Requires master firmware 3.60.447 or later. If this NI-device firmware is loaded on an earlier version of master firmware, the integrated device (5001) will be unavailable until the master side firmware is upgraded to 3.60.447 or later.

    Changes in this release:

    • Fixes Escape Sequence from not working correctly after a few minutes
    • Fixes "SET IO LINK <io>" command, no longer causes any conflicts


    2015-02-16
    NI-2100
    NI-3100
    NI-4100
    Novara 3000 Series ControlPads Firmware v.1.2.59 Hot Fix (Available from AMX Technical Support)

    Changes in this release:

    • Added support for CP-RMS v1.0.71
    • Increased the RMS Proxy timeout to help eliminate offline false positives.
    • Fixed issue where schedule scripts by NTP were not being triggered.
    • Fixed subnet mask issues with DHCP servers that require the subnet mask parameter in initial DHCP request.
    • Fixed issue where 0x20 was shown as 0x00 in RS232 Output ports.
    • Fixed large serial data coming back from projector on matching queries. The problem manifests as scripts not running when buttons are pressed.
    • Fixed potential lockup issue when the keypad is hit with random UDP traffic. Previously, the keypad could hang when generating the ICMP port unreachable response.
    • Fixed a lockup issue when the user disconnects from the telnet port after entering the username but before entering the password.
    • Fixed a lockup issue when a socket is opened to the DCS port and then immediately reset.
    • Fixed a lockup issue on the http port (80) when processing URL strings that exceeded 125 characters. Added more array bound checking to internal buffers and improved handling of socket return codes.
    • Reenabled the software and hardware watchdogs.
    • Added new telnet commands (watchdog on, watchdog off) to manually turn the watchdog on/off. State persists through system reboots.
    • Fixed issue where serial commands longer than 8 characters were sometimes being corrupted when interrogation was turned on.
    • Fixed issue where keypad could hang when receiving large ping packets. Large pings will now be truncated.

    2015-03-02
    CP-3006
    CP-3008
    CP-3017-NA
    CP-3017-TR-US
    NXA-WAP1000 Firmware Firmware v.9.7.1.0.17 Hot Fix (Available from AMX Technical Support)

    Changes in this Release:
    This firmware is for updating the WAP1000 standalone. This is not for use with a Zone Director. Any WAP100 managed by a Zone Director should automatically update its firmware.


    2015-02-06
    NXA-WAP1000
    NXB-KNX Communications Gateway Firmware v.2.0.28 Hot Fix (Available from AMX Technical Support)

    Prerequisites:

    • You must install to v2.0.23 before upgrading to v2.0.28
    • An active KNX connection is required to ensure that the upgrade completes successfully
    • If v2.0.20 through v2.0.28 is running, YOU MUST INSTALL TO V2.0.19 BEFORE DOWNGRADING TO V2.0.15 OR EARLIER

    Changes in this Release:
    NXB-KNX will no longer try to resend messages, even if a NACK is received. This is done to comply with KNX standards.


    2015-07-14
    NXB-KNX
    NXP-TPI/4 Firmware v.2.6.34 Hot Fix (Available from AMX Technical Support)

    New Features:

    • Element One (serial)
    • Eizo 17 inch Flexscan (usb)
    • Smart ID350 (usb)
    • Wacom DTF-521, DTF/PL 720 (+ many others - none to validate with) (usb)

    2013-07-01
    NXP-TPI/4
    NXR-ZGW NetLinx ZigBee Pro Gateway Firmware v.3.01.17 Hot Fix (Available from AMX Technical Support)

    1. For the proper operation of all devices, it is recommended that all devices be brought up to the most current firmware version.

    2. Loading procedures for v3.01.17:

    When upgrading from any version less than v3.00.00:

    1. Upgrade to v3.00.00 first (example: v1.01.20 -> v3.00.00)
    2. The upgrade from v3.00.00 to v3.01.16 will require two loads of the file SW5791_01A_NXR_ZGW_v3_01_16.kit. The first load will fail after the third file is transferred with the NetLinx error message "Transfer Aborted - Unsupported file type." After getting this error message, reboot the gateway and verify that the NetLinx OnLine Tree shows v3.01.12 for the version on the gateway. Transfer file SW5791_01A_NXR_ZGW_v3_01_16.kit to the gateway a second time with the "Reboot Device" box checked in NetLinx. This time the entire kit file will transfer. After the gateway reboots, it will download the firmware to the radio. This will take approximately two minutes.
    3. Load SW5795_92_ZIGBEE_END_DEVICE_v3_01_05.kit -- a gateway reboot IS NOT necessary after sending this file.
    4. Load SW5791_07_ZIGBEE_REPEATER_v3_01_05.kit -- a gateway reboot IS NOT necessary after sending this file.

    When upgrading from v3.00.00:

    1. The upgrade from v3.00.00 to v3.01.16 will require two loads of the file SW5791_01A_NXR_ZGW_v3_01_16.kit. The first load will fail after the third file is transferred with the NetLinx error message "Transfer Aborted - Unsupported file type." After getting this error message, reboot the gateway and verify that the NetLinx OnLine Tree shows v3.01.16 for the version on the gateway. Transfer file SW5791_01A_NXR_ZGW_v3_01_16.kit to the gateway a second time with the "Reboot Device" box checked in NetLinx. This time the entire kit file will transfer. After the gateway reboots, it will download the firmware to the radio. This will take approximately two minutes.
    2. Load SW5795_92_ZIGBEE_END_DEVICE_v3_01_05.kit -- a gateway reboot IS NOT necessary after sending this file.
    3. Load SW5791_07_ZIGBEE_REPEATER_v3_01_05.kit -- a gateway reboot IS NOT necessary after sending this file.

    When upgrading from v3.01.07:

    1. Transfer the file SW5791_01A_NXR_ZGW_v3_01_16.kit to the gateway via NetLinx with the "Reboot Device" box checked in NetLinx.

      It is not necessary to reload SW5795_92_ZIGBEE_END_DEVICE_v3_01_05.kit or SW5791_07_ZIGBEE_REPEATER_v3_01_05.kit since these files have not changed in this release.
    2. Recommission all devices on the network.

    Prerequisites:

    • NXR-ZGW firmware v3.00.00
    • Zigbee Coordinator firmware v3.00.00
    • NXR-ZRP firmware v3.00.00
    • R4 ZigBee module firmware v3.00.00

    CHANGES in this Release:

    • Fixes the "auto-release" bug by sending correct system number information
    • Includes zero-config fix
    • Icsp may now use ports other than 1319
    • Includes two new features
      1. May send Netlinx command to Gateway to turn Gateway to "Joinable"
        -- send_command <device>, 'Join'
      2. May send Netlinx command to Gateway to make a connect R4 bind to a different Gateway (must make other gateway joinable with previous command or go on website and click joinable)
        -- send_command <device>, 'Bind, <R4 mac address>, <new gateway extPanId>, [optional]<AESkey>'
        -- ex) send_command 11383, 'Bind, 00:0d:6f:00:00:c6:11:d7, AZG70010' //no password
        -- ex) send_command 11383, 'Bind, 00:0d:6f:00:00:c6:11:d7, AZG70010, aa:c9:9a:cb:61:ca:70:e7:13:df:ee:6f:d6:42:59:86'

    KNOWN ISSUES:

    • On systems that have one gateway and no repeaters, the remotes can become inoperable under extreme amounts of traffic (for example, 30 messages every two seconds to each of six remotes). Rebooting these devices will bring them back online.
    • Setting the gateway device number to 0 can cause it to not be correctly recognized by the master on master firmware releases less than v3.50.430.
    • The gateway does not currently support NDP mode for master connections.
    • In high traffic situations remotes can appear on the gateway commissioning page, even though they are commissioned. This has no impact on the actual operation of the remotes.
    • In some cases, the R3 power source will show as "Unknown" on the gateway web pages when the R3 is in its cradle. This issue does not impact the functionality of the remote or the gateway.
    • If using an ICSP port other than 1319, downgrading to firmware versions prior to 3.01.17 can cause the gateway to be unable to connect until it is reset to defaults. Setting the port to 1319 prior do downgrading the firmware avoids this issue.


    2012-01-05
    NXR-ZGW
    NXR-ZGW-PRO
    Mio Modero R-4 Firmware v.3.01.48 Hot Fix (Available from AMX Technical Support)

    Changes in this release:

    • Fixed several issues with the touch rail and tilt sensor implementation that was causing the Mio-R4 Remote to not immediately wake up when touched and/or tilted.
    • Fixed issue that was causing false wakeup events. Internal flags were not cleared correctly when the Mio-R4 Remote went to sleep. This led to a false wakeup event when the Mio-R4 Remote started processing an unrelated event.
    • Fixed issue where the Mio-R4 Remote would always stay awake due to an internal timer that was not being handled correctly.
    • Implemented a more reliable keypad scanner algorithm resulting in quicker responses to keypresses.
    • Changed the Mio-R4 Remote where it will not appear to wake up when it reconnects to an NI-Controller. The Mio-R4 Remote previously would have turned on the LCD display and the keypad light on wireless events such as a reboot of the Zigbee Gateway.
    • Changed the Mio-R4 Remote where it will now only send the START string on bootup. Previous versions of firmware would send the START string everytime the Mio-R4 Remote reconnected to the Ni-Controller
    • Changed the Mio-R4 Remote where it will now reboot when an internal fault is detected during bootup. Previous versions of firmware would cause the "fast flash" behavior of the power button light.
    • Enabled the hardware watchdog and set it up to trigger is the master connection is lost for more than 10 minutes.
    • Changed the power button reboot time to 7 seconds.
    • Fixed an issue with the watchdog not resetting on soft reboots
    • Fixed an issue with the watchdog not being paused when device enters Standy mode with Sleep on Display Timeout enabled

    Programming Information:

    1. If the current firmware on the Mio-R4 Remote is anything less than 3.00, then load the SW0148_01B_MIOR4_ZIGBEE_MODULE_3_00_00.kit file first. If SW0148_01A_MIOR4_3_00_00.kit is accidentally loaded first, the radio will be unable to communicate with the Mio-R4 Remote host processor and cannot be upgraded. In this case, the Mio-R4 Remote host processor will have to be downgraded to an older version of the firmware and then upgraded again with the radio being upgraded first. If the current firmware on the Mio-R4 Remote is 3.00.00 or greater, the firmware may be loaded in any order.
    2. If the current firmware on the Zigbee Gateway is anything less than 3.00, then load the SW5791_01A_NXR_ZGW_3_00_00.kit file first. If the current firmware on the Zigbee Gateway is 3.00.00 or greater, the firmware may be loaded in any order


    2015-09-11
    MIO R-4
    RoomBook Scheduling Touch Panel Firmware v. 1.0.5 Hot Fix (Available from AMX Technical Support)

    Changes in this release:

    • Enhanced certificate support for scheduling platforms. Resolves "Trust anchor for certification path not found" error.
    • Enhanced troubleshooting debug logs for Microsoft Exchange and Office 365 installs. Utilize the "ewstrace on" SSH command to turn on extra EWS logs. After running this command, the output of "msg on" will have more details.
    • Enabled access to settings when panel has a network/calendar error. This is accomplished by pressing the top bar of the screen (or clicking via VNC) for 5 seconds.


    2016-07-07
    RMBK-1001
    RMBK-701
    TPI-PRO, TPI-PRO-DVI Firmware v.2.6.158 Hot Fix (Available from AMX Technical Support)

    USB Touch Monitor Drivers added in this release:

    • ELO ET-2243L-8UWA
    • Planar PCT2265 using Advanced Silicon CoolTouch USB Controller
    • Planar PCT2785 using 3M MicroTouch USB controller
    • Newer versions of the SMART Podium 518
    • NextWindow 5613 Optical Overlay
    • Hatteland HD 15T21STD
    • Ilitex Iyama USB touch driver support added
    • 46" NEC v463 model USB touch support added
    • Esterline - Medigenic USB keyboards (Model #'s 104C, 104E)

    Serial Touch Monitor Drivers added in this release:

    • 3M MicroTouch SX112 in pen-only touch mode (MicroTouchSX112POHandler).
    • 3M MicroTouch SX112 in finger-only touch mode (MicroTouchSX112FOHandler).
    • 3M MicroTouch SX112 in pen/finger touch mode (MicroTouchSX112PFHandler).

    Features added in this release:

    • USB Takenote Save to USB only feature added
    • Added a "toggle usb touch" cli command that will toggle the USB touch state. When USB touch is in the disabled state, USB devices will not override any serial touch driver selection made by the user. The current USB touch state can be viewed with the "show usb touch" cli command.

    Bug Fixes in this release:

    • eGalaxTouchHandler_9600 RS232 Driver, powering off the device causes g4 touch to break
    • extron annotator DVI connection causes boot failure to hang at AMX logo
    • Elo 'No Signal Detected' on output when display goes to sleep fixed
    • SMART Podium 518 - Fixed an issue where power cycling the monior or unplugging / plugging in the USB from the monitor would cause the TPI-Pro to crash
    • Fixed an issue with the Planar PT2275SW that would cause pass through input to become laggy
    • Fixed an issue where dynamic image would fail to load if the TP4 file had been originally created for a newer panel type such as Modero X and then saved as a TPI-PRO

    Programming Information:
    To load this firmware successfully, a valid DVI connection should be made to get the unit to boot and connect to the AMX master The Driver kit should be loaded as well after this kit file.


    2015-09-11
    TPI-PRO
    TPI-PRO-DVI
    ViewStat Color Communicating Thermostat Firmware v.3.12 Hot Fix (Available from AMX Technical Support)
    • Fixes - Viewstats unable to change the temperature at night. Users couldn't change the temperature, when in "Sleep" program schedule, while in program mode. The only way to adjust it was to change it to permanent hold.
    • Fixes - ViewStats falling back into sleep set points during other program modes time frame. Once the setpoint with the minutes other than zero was encountered the stat would revert to the previous set point for the duration of the minutes from the top of the hour to that minute mark.
    • Fixes - Comfort recovery did not come on until 12am. When 2-hour cycle occurs over midnight comfort recovery did not come on until 12a when 2-hour cycle occurs over midnight.
    • Fixes - AM is AM but PM is AM. If you set program mode times to be all AM the thermostat Program time would still trigger like they were PM times.

    Firmware prerequisite is v3.01 or greater

    To update the firmware, Download firmware file SW2050-v3.12-app.tsk followed by SW2050-01-TSK_v3.12.tsk


    2012-02-24
    ENV-VST-C