Release Notes
DXLink 4K HDMI Receiver Module
FG#: FG1010-510 (DX-RX-4K)
Release Date: 9/20/2017
Firmware Version: v2.2.29
1. Prerequisites
2. Features added in this release
3. Fixes in this release:
4. Known Issues
5. Programming Information
6. Notable Points
----------------------------------------------------------
1. Prerequisites
----------------------------------------------------------
- Directly connected DX-TX should use v1.8.28 (or later).
- Directly connected SDX must use v1.4.9 (or later).
- Directly connected 4K SDX must use v2.1.34 (or later).
- Enova DGX 800/1600/3200/6400 must have v3.2.19 (or later)
- DVX Switcher Series FW should be v1.6.76 (or later)
- NX Master FW should be v1.4.90 (or later)
- NetLinx Studio v4.3.1519 (or later)
----------------------------------------------------------
2. Features added in this release:
----------------------------------------------------------
- none
----------------------------------------------------------
3. Fixes in this release:
----------------------------------------------------------
- Fixed issue to allow multiple vendors of SPI Flash.
Changes from 2.2.28
- Fixed issue where random monitors (NEC) would still not
go to sleep with the previous firmware
Changes from 2.2.27
- Fixes scenarios where monitors will not go to sleep
when no video is present on the input (4k wallplate,
no dxlink cable)
Changes from 2.2.26
- SDX->DX-RX-4K improved switching speed
Changes from 2.2.25
- Fixed issue where output blue screen occurs when monitor
should be asleep, with some displays
- Improved master connection reliability
----------------------------------------------------------
4. Known Issues
----------------------------------------------------------
- ICSLAN port is not disabled when dipswitch 1 is OFF and
the RX is connected to a DGX.
----------------------------------------------------------
5. Programming Information
----------------------------------------------------------
- Upgrade Note: Due to a HW ID change, this kit will fail
if upgrading from a version earlier than v2.2.29.
Simply reboot the 4kRX and confirm the FW version in
the Online Tree is correct. If incorrect, resend the kit.
- Downgrade Note: Due to the HW ID change, 4KRX's with a
factory firmware image of v2.2.29 or later will not be
able to downgrade to versions earlier than v2.2.29.
- To see what factory image is loaded, open a telnet
session to the RX and type: fwimages - The version
shown in slot 0 is the factory version.
- The FPGA portion of the KIT file firmware download can
take up to 10 minutes in itself. Please be patient during
upgrades.
- PLEASE reference Appendix A (Upgrading the Firmware) in
the DXLink Instruction Manual for more information.
----------------------------------------------------------
6. Notable Points
----------------------------------------------------------
- PLEASE READ the documentation in regard to the DIP
switches located on the DXLink 4K HDMI Receiver Module
before attempting to connect to the network.