Modero NXD-CV10 / NXT-CV10 Touch Panel Firmware v2.86.29

Last Updated: 3月16日

Important: Panels with more than 1Gb Compact Flash cards should not be downgraded to any version below 2.86.26. This information can be retrieved via Setup pages (Information - File System), or using telnet - (disk free).

Prerequisites: None.

Changes in this release:

Boot:

  • Added support for large (2 GB or greater) Compact Flash Cards.

 

User Interface:

  • New touch calibration algorithm which provides more accuracy and corrects for nonlinear error in the touch overlays. The new algorithm adds more points to the touch calibration.

 

Setup Pages:

  • Added new calibration page compatible with the new touch calibration.

 

Hot Fix for the Modero 10" CV Touch Panels Firmware (v.2.86.41 Available from AMX Technical Support)

Prerequisites:
None.

Changes in this release:

  • Fixed an issue where the panel could repeatedly fall off line or reboot due to an issue with the watchdog monitoring system. The watchdog is fixed and updated with a logging feature that will persist over reboots for future analysis.
  • Fixed an issue where the Ethernet driver could crash in high traffic environments
  • Fixed issue with bar graphs set using the ^GLH & ^GLL send commands and the handling of negative values.