MUSE Automator - Windows v1.1.12

Note: this is an old version. The current version is: MUSE Automator - Windows v1.3.17. ×

Last Updated: Oct 07

Product Name: MUSE Automator (Windows)

Current Version: 1.1.12
Release Date: 2024-09-26


-----------------------------------------------------------
System Requirements
----------------------------------------------------------

- Windows 10+ 64-bit
- 2 GHz processor
- 8 GB RAM
- 2-4 GB disk space


-----------------------------------------------------------
Software Dependencies
----------------------------------------------------------

The following dependencies must be installed prior to installing MUSE Automator (see user guide).
Automator has been tested with varying versions, but the following versions are recommended:

NodeJS v20.11.1+
NPM v10.2.4+
GIT v2.43.0+


----------------------------------------------------------
New Features in this release
----------------------------------------------------------

Version 1.1.12

- MUSE Automation Controller (MU-xxxx) firmware required: 1.2.65
** MUSE Automator 1.1.12 will not work with firmware older than 1.2.65 **

- Node-RED upgraded to 4.0.2; https://github.com/node-red/node-red/releases
- Added UI Feedback node to replace deprecated Navigate node
- Added Panel Grouping to assist with flows using multiple touch panels
- Improved TP file mapping for pages, pop-up, & subpages


----------------------------------------------------------
Bug Fixes in this release
----------------------------------------------------------

- Resolved: Node properties do not persist on Edit
- Disabling the Programming Access still allows connection to Automator
- Command node relay state does not persist on edit
- Error message on startup when controller set to secure (https)
- Panel pages missing in UI node
- Unable to start Node-RED on controller


----------------------------------------------------------
Previous Versions
----------------------------------------------------------

Version 1.0.54

- MUSE Automation Controller (MU-xxxx) firmware required: 1.1.43
- Initial Release

Version 0.9.47

- BETA release


----------------------------------------------------------
Known Issues and Caveats
----------------------------------------------------------

- There is a view syncing issue in the Push/Pull Tray where the Push/Pull Tray might not accurately reflect the true status of the system. To get the view to sync properly, simply click on the Push/Pull button a second time after pushing, pulling, starting, stopping, or deleting a project.

- There is a Controller Node view syncing issue where the Controller may show disconnected on the workspace even though it is connected. Opening the node and then pressing Connect button again may resolve this sync issue.

- Custom and string events may not trigger correctly on AMX Varia panels if they are offline when a MUSE controller has rebooted. To work around this, reboot the controller while the panels are online.

- On larger projects with more nodes and flows, you may experience more slow transfer speeds. Transfer speeds are always going to be relative to the size of the project.

- A project cannot be deleted unless another project is running in the Push/Pull Tray

- Stopping a locally running project will cause disconnection from the remote MUSE controller

- You may sometimes experience issues when using certain third-party nodes after you've pushed a project to the controller. This issue is not consistently reproducible and is under investigation.