NXA-PDU-1508-8

Power Distribution Unit (110V/220V)

Larger Images

The innovative Power Distribution Unit (PDU) now allows you to control the rack as well as control the room. This PDU adds a basic level of control by allowing remote reset of devices via a power cycle, reducing the need to send staff to a customer site. By managing power delivery, the PDU monitors energy consumption of each connected component and restricts power to any or all devices when not in use. With 8 individually monitored and controlled AC outlets, built-in 12 Volt power supply, 2 sets of 4 AxLink Bus Strips, and power monitoring for each outlet, the PDU is flexible and can reduce wasteful standby power usage. Native NetLinx control over AxLink integrates the PDU with AMX Control systems and Resource Management Suite (RMS).

Common Applications

Ideal for commercial and residential installations wanting to reduce energy usage costs, minimize their carbon footprint and protect valuable electronics. With AC and AxLink power, current sensing, and available temperature monitoring, this all-in-one easily adds both convenience and a Green element to installations.

Downloads

  Version Language Size Uploaded
Data Sheet     361 KB Jul 06, 2018
CAD Drawings
Pictorial Drawing - NXA-PDU-1508-8 Power Distribution Unit (PDF)     292 KB Apr 09, 2018
Pictorial Drawing - NXA-PDU-1508-8 Power Distribution Unit (DXF)     1.82 MB Apr 09, 2018
Bim Objects
NXA-PDU-1508-8 - BIM Object     Aug 12, 2019
Software
NXA-PDU-1508-8 Power Distribution Unit Firmware 2.13.04    34.2 KB Mar 15, 2018
Quick Reference Guides
Operation/Reference Guide - NXA-PDU-1508-08 Power Distribution Unit (240V / 10A)     423 KB Mar 26, 2018
Operation/Reference Guide - NXA-PDU-1508-08 Power Distribution Unit (110V/220V)     373 KB Mar 26, 2018
Quick Start Guides
Quick Start Guide - NXA-PDU-1508-08 Power Distribution Unit (110V/220V)     217 KB Mar 26, 2018
A&E (Architectural & Engineering) Specifications
A&E Spec - NXA-PDU-1508-8 Power Distribution Unit     44.5 KB Jun 27, 2018

If any of the links above result in strange characters in your browser, please right-click the file to save it to your computer.

Features

  • Individually Controlled Outlets - Allows a remote reboot for devices in the rack reducing on-site service calls
  • Power Management of Connected Devices - Reduces standby energy usage (vampire power/phantom load)
  • Built-in Power Current Sensing on Each AC Outlet - Makes it easy to tell if a device is powered on or off
  • Switched and Monitored AxLink Bus Strips - Allows power and switching of AxLink or 12V powered devices (in banks of four)
  • Native NetLinx Device - Simplifies integration
  • Connect to Remote Server - Enables the PDU to monitor the temperature in the equipment rack

Specifications

Dimensions (HWD) 1 3/16" x 17" x 9 11/16 (3.0 cm x 43.2 cm x 9.7 cm), RU: 1
Power Connector Powered via 100-240 VAC, 50-60 Hz mains power on an IEC-320 C-14 connector
Required Voltage 100 to 240 VAC, 47-63 Hz
AC Current Input 12 AMPS @ 110V - 120V, 10 AMPS @ 220V - 240V
AC Current Outputs 10 AMPS Single Outlet @ 110 VAC, 12 AMPS Max Unit Output @ 110 VAC, 8 AMPS Single Outlet @ 220 VAC, 10 AMPS Max Unit Output @ 220 VAC
Front Panel Components Master Reset Pushbutton, AxLink Status LED, Outlet Status LEDs, AxLink Bus Status LEDs. See Data Sheet for details.
Rear Panel Connectors Intl. Power Inlet (1) Connector Type: IEC C-14, Intl. Power Outlets (8) Connector Type: IEC C-13, AxLink Master Connectoor, AxLink Device Connectors (8), Remote Temperature Sensor (RTS) Input. See Data Sheet for details.
FG Numbers FG673-01